Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes

被引:222
作者
Burmeister, JJ
Gerhardt, GA [1 ]
机构
[1] Univ Kentucky, Albert B Chandler Med Ctr, Dept Anat & Neurobiol, Lexington, KY 40536 USA
[2] Univ Kentucky, Albert B Chandler Med Ctr, Dept Neurol, Ctr Sensor Technol, Lexington, KY 40536 USA
[3] Univ Kentucky, Albert B Chandler Med Ctr, Morris K Udall Parkinsons Dis Res Ctr Excellence, Lexington, KY 40536 USA
关键词
D O I
10.1021/ac0010429
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A self-referencing technique utilizing two microelectrodes on a ceramic-based multisite array is employed for confirmation and elimination of interferences detected by enzyme-based microelectrodes. The measurement of L-glutamate using glutamate oxidase was the test system; however, other oxidase enzymes such as glucose oxidase can be employed. One recording site was coated with Nafion with L-glutamate oxidase and bovine serum albumin (BSA) cross-linked with glutaraldehyde while the other had Nafion with BSA cross-linked with glutaraldehyde. Differences in the chemistry of the two recording sites allowed for identification and elimination of interfering signals to be removed from the analyte response. The electrode showed low detection limits (LOD = 0.98 +/- 0.09 muM, signal-to-noise ratio of 3), fast response tithes (T-90 similar to1 s), and excellent linearity (R-2 = 0.999 +/- 0.000) over the concentration range of 0-200 muM for calibrations of L-glutamate in vitro. The selectivity and dimensions of the multisite electrode allow in vivo glutamate measurements. This electrode has been applied to in vivo measurements of the clearance of locally applied glutamate and release of glutamate in the prefrontal cortex of anesthetized rats. In addition, a similar approach has been applied to the development of a microelectrode for measures of glucose.
引用
收藏
页码:1037 / 1042
页数:6
相关论文
共 36 条
  • [1] ALBERY WJ, 1991, CIBA F SYMP, V158, P55
  • [2] Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes
    Alvarez-Crespo, SL
    Lobo-Castanon, MJ
    Miranda-Ordieres, AJ
    Tunon-Blanco, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (08) : 739 - 747
  • [3] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [4] DETERMINATION OF L-GLUTAMATE AND L-GLUTAMINE IN PHARMACEUTICAL FORMULATIONS BY AMPEROMETRIC L-GLUTAMATE OXIDASE BASED ENZYME SENSORS
    BOTRE, F
    BOTRE, C
    LORENTI, G
    MAZZEI, F
    PORCELLI, F
    SCIBONA, G
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) : 679 - 686
  • [5] Ceramic-based multisite microelectrodes for electrochemical recordings
    Burmeister, JJ
    Moxon, K
    Gerhardt, GA
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (01) : 187 - 192
  • [6] CHEN CY, 1991, ANAL CHIM ACTA, V243, P9
  • [7] Direct immobilization of glutamate dehydrogenase on optical fiber probes for ultrasensitive glutamate detection
    Cordek, J
    Wang, XW
    Tan, WH
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (08) : 1529 - 1533
  • [8] COMPARISON OF 2 FIBEROPTIC L-GLUTAMATE BIOSENSORS BASED ON THE DETECTION OF OXYGEN OR CARBON-DIOXIDE, AND THEIR APPLICATION IN COMBINATION WITH FLOW-INJECTION ANALYSIS TO THE DETERMINATION OF GLUTAMATE
    DREMEL, BAA
    SCHMID, RD
    WOLFBEIS, OS
    [J]. ANALYTICA CHIMICA ACTA, 1991, 248 (02) : 351 - 359
  • [9] REGIONAL EFFECTS OF AGING ON DOPAMINERGIC FUNCTION IN THE FISCHER-344 RAT
    FRIEDEMANN, MN
    GERHARDT, GA
    [J]. NEUROBIOLOGY OF AGING, 1992, 13 (02) : 325 - 332
  • [10] GARRIS PA, 1986, NEUROMETHODS SERIES, V27, P179