Purpose: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters. Methods: Fifty temporary IVC filters (Gunther, Gunther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis. Results: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis. Conclusion: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.
引用
收藏
页码:464 / 469
页数:6
相关论文
共 24 条
[1]   COMPLICATIONS OF VENA-CAVA FILTERS [J].
ATHANASOULIS, CA .
RADIOLOGY, 1993, 188 (03) :614-615
[2]   CATHETER MALFUNCTION AND THROMBUS FORMATION ON DOUBLE-LUMEN HEMODIALYSIS CATHETERS - AN INTRAVASCULAR ULTRASONOGRAPHIC STUDY [J].
BOLZ, KD ;
FJERMEROS, G ;
WIDEROE, TE ;
HATLINGHUS, S .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1995, 25 (04) :597-602
[3]   WORSENING OF PROXIMAL THROMBOSIS AFTER INSERTION OF A TEMPORARY CAVA FILTER [J].
CARCONE, B ;
PERNES, JM ;
CARCOPINO, JM ;
CHOLLET, D ;
POUILLARD, F .
REVUE DE MEDECINE INTERNE, 1995, 16 (05) :351-353
[4]   EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVAL FILTER - WORK IN PROGRESS [J].
DARCY, MD ;
CARDELLA, JF ;
HUNTER, DW ;
SMITH, TP ;
CASTANEDAZUNIGA, WR ;
LUND, G ;
AMPLATZ, K .
RADIOLOGY, 1986, 161 (03) :611-614
[6]   EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER [J].
EPSTEIN, DH ;
DARCY, MD ;
HUNTER, DW ;
COLEMAN, CC ;
TADAVARTHY, SM ;
MURRAY, PD ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1989, 172 (01) :105-110
[7]   PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS - FOLLOW-UP OF 7 DESIGNS IN 320 PATIENTS [J].
FERRIS, EJ ;
MCCOWAN, TC ;
CARVER, DK ;
MCFARLAND, DR .
RADIOLOGY, 1993, 188 (03) :851-856
[8]   GUNTHER VENA-CAVAL FILTER - RESULTS OF LONG-TERM FOLLOW-UP [J].
FOBBE, F ;
DIETZEL, M ;
KORTH, R ;
FELSENBERG, D ;
BENDER, S ;
HAMED, M ;
LAASS, C ;
SORENSEN, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) :1031-1034
[9]   A physiologic in vitro model of the inferior vena cava with a computer-controlled flow system for testing of inferior vena cava filters [J].
Jaeger, HJ ;
Mair, T ;
Geller, M ;
Kinne, RK ;
Christmann, A ;
Mathias, KD .
INVESTIGATIVE RADIOLOGY, 1997, 32 (09) :511-522
[10]   PROPHYLACTIC GREENFIELD FILTER PLACEMENT IN SELECTED HIGH-RISK TRAUMA PATIENTS [J].
KHANSARINIA, S ;
DENNIS, JW ;
VELDENZ, HC ;
BUTCHER, JL ;
HARTLAND, L .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (03) :231-236