Device for the reversed-phase separation and on-target deposition of peptides incorporating a hydrophobic sample barrier for matrix-assisted laser desorption/ionization mass spectrometry

被引:21
作者
Chen, VC
Cheng, K
Ens, W
Standing, KG
Nagy, JI
Perreault, H [1 ]
机构
[1] Univ Manitoba, Dept Chem, Winnipeg, MB R3T 2N2, Canada
[2] Univ Manitoba, Manitoba Ctr Proteom, Winnipeg, MB R3T 2N2, Canada
[3] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T 2N2, Canada
[4] Univ Manitoba, Dept Physiol, Winnipeg, MB R3T 2N2, Canada
关键词
D O I
10.1021/ac035014c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation of peptide mixtures from proteolytic cleavage is often necessary prior to mass spectrometry (MS) to enhance sensitivity and peptide mapping coverage. When buffers, salts, and other higher abundance peptides/contaminants are present, competition for charge during the electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) processes can lead to ion suppression for the targeted analyte(s). In this note, a simple reversed-phase microcolumn sample separation and deposition device (Sep-Dep) is described. The use of this device improves or renders possible the analysis of complex or contaminated peptide mixtures by MALDI-MS. The method is simple and inexpensive and utilizes single-use low-cost Geloader-type columns packed with reversed-phase material. The device described utilizes an open column, allowing for a gradient or narrow-step gradient to be applied by any solvent delivery system or manually with a pipet. A key feature of the device is a deposition chamber that can be custom-built to hold any MALDI target. The Sep-Dep device is attached directly to an in-house vacuum fine and draws solvent from the open-ended LC column. The elution of separated peptides is performed directly onto a target that has been treated with a hydrophobic barrier. This barrier effectively isolates fractions and improves the quality and morphology of the matrix crystals. The method produces efficient separations of proteolytic peptides, significantly reducing signal suppression effects in MALDI.
引用
收藏
页码:1189 / 1196
页数:8
相关论文
共 34 条
[1]   APPLICATION OF CAPILLARY ELECTROPHORESIS, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, ONLINE ELECTROSPRAY MASS-SPECTROMETRY AND MATRIX-ASSISTED LASER-DESORPTION IONIZATION-TIME OF FLIGHT MASS-SPECTROMETRY TO THE CHARACTERIZATION OF SINGLE-CHAIN PLASMINOGEN-ACTIVATOR [J].
APFFEL, A ;
CHAKEL, J ;
UDIAVAR, S ;
HANCOCK, WS ;
SOUDERS, C ;
PUNGOR, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :41-60
[2]   Enhanced detection of phosphopeptides in matrix-assisted laser desorption/ionization mass spectrometry using ammonium salts [J].
Asara, JM ;
Allison, J .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (01) :35-44
[3]  
Ayed A, 1998, RAPID COMMUN MASS SP, V12, P339, DOI 10.1002/(SICI)1097-0231(19980415)12:7<339::AID-RCM163>3.0.CO
[4]  
2-6
[5]   Restricted access chromatographic sample preparation of low mass proteins expressed in human fibroblast cells for proteomics analysis [J].
Bratt, C ;
Lindberg, C ;
Marko-Verga, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 909 (02) :279-288
[6]  
CHEN VC, 2003, HUPO 2 ANN IUBMB 11
[7]  
CHEN VC, 2003, 51 ASMS C MASS SPECT
[8]   Differential screening and mass mapping of proteins from premalignant and cancer cell lines using nonporous reversed-phase HPLC coupled with mass spectrometric analysis [J].
Chong, BE ;
Hamler, RL ;
Lubman, DM ;
Ethier, SP ;
Rosenspire, AJ ;
Miller, FR .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1219-1227
[9]  
Foret F, 2002, PROTEOMICS, V2, P360, DOI 10.1002/1615-9861(200204)2:4<360::AID-PROT360>3.0.CO
[10]  
2-Y