Adaptive digital spectroscopy in programmable logic

被引:25
作者
Geraci, A [1 ]
Di Odoardo, A [1 ]
Riboldi, S [1 ]
Ripamonti, G [1 ]
机构
[1] Politecn Milan, Dept Elect, I-20133 Milan, Italy
关键词
adaptive digital filtering; digital spectroscopy; power dissipation; processing speed; programmable logic devices; spatial computing architectures;
D O I
10.1109/23.901184
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
High data rate in nuclear spectroscopy can be achieved by using digital shaping techniques, Currently, the use of field-programmable gate arrays as digital processors is hugely increasing, especially in real time applications. In this paper, we deal with the problem of the minimization of the computation burden, in order to allow the use of the least possible hardware, which in turn allows the minimization of power dissipation, size etc, of the processing machine. In order to get at-most advantages of spatial computing in programmable devices, data-path structures of temporal computing process techniques have been revised, Among the improvements consequent to the optimization of architectures, we address three topics: reduction of processing speed, resource saving, and adaptive dynamic management of digital filters length for increasing resolution.
引用
收藏
页码:2765 / 2772
页数:8
相关论文
共 14 条
[1]
High-accuracy fit of the poles of spectroscopy amplifiers designed for mixed analog-digital filtering [J].
Bittanti, S ;
Gatti, E ;
Ripamonti, G ;
Savaresi, SM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (02) :125-133
[2]
Optimum time-limited filters for input signals of arbitrary shape [J].
Gatti, E ;
Geraci, A ;
Ripamonti, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (02) :226-230
[3]
Automatic synthesis of optimum filters with arbitrary constraints and noises: A new method [J].
Gatti, E ;
Geraci, A ;
Ripamonti, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (01) :117-127
[4]
AN ANALOG-TO-DIGITIAL CONVERSION BASED ON A MOVING WINDOW DECONVOLUTION [J].
GEORGIEV, A ;
GAST, W ;
LIEDER, RM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1116-1124
[5]
GEORGIEV A, 1993, IEEE T NUCL SCI, V40, P534
[6]
An automatic initialization procedure for real-time digital radiation spectrometry [J].
Geraci, A ;
Ripamonti, G ;
Pullia, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 403 (2-3) :455-464
[7]
A comparative study of the energy resolution achievable with digital signal processors in X-ray spectroscopy [J].
Geraci, A ;
Zambusi, M ;
Ripamonti, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (02) :731-736
[8]
DIGITAL PULSE PROCESSOR USING A MOVING AVERAGE TECHNIQUE [J].
JORDANOV, V ;
KNOLL, GF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :764-769
[9]
DIGITAL PULSE-SHAPE ANALYZER BASED ON FAST SAMPLING OF AN INTEGRATED CHARGE PULSE [J].
JORDANOV, VT ;
KNOLL, GF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :683-687
[10]
DISCUSSION ON OPTIMUM FILTERING IN NUCLEAR RADIATION SPECTROMETERS [J].
KOEMAN, H .