Stability of silica-based, monofunctional C-18 bonded-phase column packing for HPLC at high pH

被引:30
作者
Kirkland, JJ
机构
[1] Rockland Technologies, Inc., Newport, DE 19804
关键词
D O I
10.1093/chromsci/34.7.309
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Previous studies have shown that nonendcapped, monofunctional bonded-phase column packings made from silica supports prepared by the sol-gel method have surprising stability at up to pH 10 in certain mobile phases. Even when purged with NaOH at pH 12, these columns demonstrate properties that suggest that useful chromatographic separations might be feasible under such conditions. Separations at high pH (pH 10 or greater) are attractive for separating certain basic compounds. Such solutes would be in the free-base form, which would minimize potential deleterious interaction with unreacted silanol groups on the silica support. Results from this study indicate that use of lithium-based buffers may reduce the dissolution of silica supports and thus enhance column stability at high pH. Experiments also suggest that pH 12 separations with sol-gel silica supports are feasible, although such high pH operation limits column lifetime.
引用
收藏
页码:309 / 313
页数:5
相关论文
共 12 条
[1]   Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography [J].
Claessens, HA ;
vanStraten, MA ;
Kirkland, JJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :259-270
[2]  
ILER R, 1979, CHEM SILICA, P31
[3]   NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH HIGHLY PURIFIED POROUS SILICA MICROSPHERES [J].
KIRKLAND, JJ ;
DILKS, CH ;
DESTEFANO, JJ .
JOURNAL OF CHROMATOGRAPHY, 1993, 635 (01) :19-30
[4]   REVERSED-PHASE HPLC SELECTIVITY AND RETENTION CHARACTERISTICS OF CONFORMATIONALLY DIFFERENT BONDED ALKYL STATIONARY PHASES [J].
KIRKLAND, JJ ;
HENDERSON, JW .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1994, 32 (11) :473-480
[5]   HIGH PH MOBILE-PHASE EFFECTS ON SILICA-BASED REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
KIRKLAND, JJ ;
VANSTRATEN, MA ;
CLAESSENS, HA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :3-19
[6]  
KIRKLAND JJ, 1989, Patent No. 4874518
[7]  
KIRKLAND JJ, 1995, PRACTICAL METHOD DEV
[8]   IMPROVED SILICA-BASED COLUMN PACKINGS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOHLER, J ;
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :125-150
[9]   STABILITY OF SILICA PACKING MATERIALS TOWARDS A MIXED AQUEOUS ORGANIC ELUENT AT ALKALINE PH [J].
LAW, B ;
CHAN, PF .
JOURNAL OF CHROMATOGRAPHY, 1989, 467 (01) :267-271
[10]  
SNYDER JL, 1988, PRACTICAL HPLC MEHTO