The sampling efficiency of personal inhalable aerosol samplers in low air movement environments

被引:75
作者
Kenny, LC
Aitken, RJ
Baldwin, PEJ
Beaumont, GC
Maynard, AD
机构
[1] Hlth & Safety Lab, Sheffield S3 7HQ, S Yorkshire, England
[2] Inst Occupat Med Ltd, Edinburgh EH8 9SU, Midlothian, Scotland
关键词
D O I
10.1016/S0021-8502(98)00752-6
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experimental systems were developed in two laboratories for measuring the sampling efficiency of personal inhalable aerosol samplers in low aii movement environments, using sedimenting aerosols. The sampling efficiencies of four types of personal inhalable or total dust sampler were measured; the samplers chosen were the IOM sampler, the GSP conical inhalable sampler, the UK seven-hole sampler and the 37 mm closed face sampling cassette. Isolated samplers or manikin mounted samplers were slowly rotated in an aerosol chamber, whilst mounted in orientations similar to those in which they are normally used for personal sampling. Measurements were made using nine aluminium oxide test aerosols with aerodynamic diameter values ranging from 6 to 90 mu m. Reference concentrations in the aerosol chamber were measured using slowly circling sharp-edged probes with matched forward and aspiration velocities, to simulate isokinetic sampling. Sampling efficiencies for the IOM, GSP and seven-hole samplers measured using this system were generally higher than wind tunnel results previously reported at an external wind speed of 0.5 m s(-1) For the 37 mm sampler the results were generally lower than the previous wind tunnel results. Measurements made with the samplers mounted on the torso of the manikin showed positional differences in sampling efficiency, but the average sampling efficiencies were similar whether the samplers were on or off the manikin. The experimental system developed in this work is simpler and gives more reproducible results than the wind tunnel tests of samplers (mounted on a life-size manikin) that are normally used to assess personal sampler performance. Crown Copyright (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:627 / 638
页数:12
相关论文
共 19 条
[1]   Aerosol inhalability in low air movement environments [J].
Aitken, RJ ;
Baldwin, PEJ ;
Beaumont, GC ;
Kenny, LC ;
Maynard, AD .
JOURNAL OF AEROSOL SCIENCE, 1999, 30 (05) :613-626
[2]  
[Anonymous], 1995, Air quality - particle size fraction definitions for health related sampling
[3]   A survey of wind speeds in indoor workplaces [J].
Baldwin, PEJ ;
Maynard, AD .
ANNALS OF OCCUPATIONAL HYGIENE, 1998, 42 (05) :303-313
[4]  
Belyaev S. P., 1974, J AEROSOL SCI, V5, P325, DOI [10.1016/0021-8502(74)90130-X, DOI 10.1016/0021-8502(74)90130-X, /10.1016/0021-8502(74)90130-X]
[5]  
BUCHAN RM, 1986, AM IND HYG ASSOC J, V47, P825, DOI 10.1080/15298668691390728
[6]  
Cen, 1993, 4811993 BS EN
[7]   WIND EFFECTS ON PERSONAL DUST SAMPLERS [J].
CHUNG, KYK ;
OGDEN, TL ;
VAUGHAN, NP .
JOURNAL OF AEROSOL SCIENCE, 1987, 18 (02) :159-&
[8]  
DUNNET SJ, 1988, AEROSOL SCI TECHNOL, V8, P254
[9]  
HAMEED R, 1983, AEROSOL SCI TECH, V2, P69
[10]  
HINDS WC, 1980, GENERATION AEROSOLS, P171