Ultra fast trypsin digestion of proteins by high intensity focused ultrasound

被引:141
作者
López-Ferrer, D
Capelo, JL
Vázquez, J
机构
[1] Univ Autonoma Madrid, Ctr Biol Mol Severo Ochoa, Fac Biol, E-28049 Madrid, Spain
[2] Univ Nova Lisboa, REQUIMTE, Dept Quim, Fac Ciencia & Tecnol, P-2829516 Caparica, Portugal
关键词
protein digestion; high-intensity focused ultrasound; MALDI; LC-ESI-IT-MS;
D O I
10.1021/pr050112v
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Proteolytic digestion of proteins in seconds under an ultrasonic field provided by high-intensity focused ultrasound (HIFU) has been achieved. Successful in-solution and in-gel tryptic digestion of proteins in 60 s or less was demonstrated by either MALDI-TOF mass spectrometry or liquid chromatography-electrospray ion trap mass spectrometry (RP-HPLC-ESI-IT-MS/MS). The efficiency of this new procedure for protein digestion compared favorably with those attained using conventional overnight incubation methods. The performance of the method was also demonstrated by the specific identification of three proteins in a whole proteome in less than 1 h. The method greately reduces the time needed for protein digestion, is of easy implementation, environmental friendly, and economic. Adaptation of this method to on-line procedures and robotic platforms could have promising applications in the proteomics field.
引用
收藏
页码:1569 / 1574
页数:6
相关论文
共 22 条
[1]  
BERMEJO P, 2004, TRAC TRENDS ANAL CHE, V23, P9
[2]   Enzymatic probe sonication:: Enhancement of protease-catalyzed hydrolysis of selenium bound to proteins in yeast [J].
Capelo, JL ;
Ximénez-Embún, P ;
Madrid-Albarrán, Y ;
Cámara, C .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :233-237
[3]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[4]   Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs [J].
Fortier, MH ;
Bonneil, E ;
Goodley, P ;
Thibault, P .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1631-1640
[5]  
*GMBH CO KG, BANDELIN EL
[6]   Fast-response proteomics by accelerated in-gel digestion of proteins [J].
Havlis, J ;
Thomas, H ;
Sebela, M ;
Shevchenko, A .
ANALYTICAL CHEMISTRY, 2003, 75 (06) :1300-1306
[7]   A 2-D liquid separations/mass mapping method for interlysate comparison of ovarian cancers [J].
Kachman, MT ;
Wang, HX ;
Schwartz, DR ;
Cho, KR ;
Lubman, DM .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1779-1791
[8]   Mapping of an ultrasonic horn: link primary and secondary effects of ultrasound [J].
Kanthale, PM ;
Gogate, PR ;
Pandit, AB ;
Wilhelm, AM .
ULTRASONICS SONOCHEMISTRY, 2003, 10 (06) :331-335
[9]   Statistical model for large-scale peptide identification in databases from tandem mass spectra using SEQUEST [J].
López-Ferrer, D ;
Martinez-Bartolomé, S ;
Villar, M ;
Campillos, M ;
Martín-Maroto, F ;
Vázquez, J .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :6853-6860
[10]  
Mason TJ, 1999, SONOCHEMISTRY