Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs

被引:108
作者
Fortier, MH
Bonneil, E
Goodley, P
Thibault, P [1 ]
机构
[1] Univ Montreal, Inst Rec Immunol & Canc, Montreal, PQ H3C 3J7, Canada
[2] Univ Montreal, Dept Chem, Montreal, PQ H3C 3J7, Canada
[3] Capr Pharmaceut, Montreal, PQ, Canada
[4] Agilent Technol, Santa Clara, CA 95051 USA
关键词
D O I
10.1021/ac048506d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present investigation describes the analytical performances of a microfluidic device comprising an enrichment column, a reversed-phase separation channel, and a nanoelectrospray emitter embedded altogether in polyimide layers. This configuration minimizes transfer lines and connections and reduces postcolumn peak broadening and dead volumes. This compact and versatile modular nanoLC-chip system was interfaced to both ion trap and time-of-flight mass spectrometers, and its analytical potentials were evaluated in the context of proteomics applications. The figures of merit of this system in terms of peak capacity, reproducibility, sensitivity, and linear dynamic range of peptide detection were determined using tryptic digests of complex protein extracts including albumin- and immunoglobulin-depleted rat plasma samples. The analysis of peak profiles for more than 600 peptide ions reproducibly detected across replicate nanoLC-chip-MS runs (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity with RSD values of less than 0.5 and 9.1%, respectively. Variation in peptide abundance as low as 2-fold changes was identified for spiked tryptic digests present at levels of 2 - 5 fmol in plasma samples. Sensitivity measurements were performed on dilution series of protein digests spiked into rat plasma samples and provided a detection limit of 1-5 fmol. The modular concept of the microfluidic systems also facilitated the integration of two-dimensional chromatography (strong cation exchange/C-18) thereby increasing the sample loading and selectivity of the nanoLC-chip-MS system. The application of this integrated device was evaluated for complex rat plasma samples to compare the number of protein identifications obtained using one- and two-dimensional nanoLC-chip-MS/MS.
引用
收藏
页码:1631 / 1640
页数:10
相关论文
共 40 条
[1]   Toward a human blood serum proteome - Analysis by multidimensional separation coupled with mass spectrometry [J].
Adkins, JN ;
Varnum, SM ;
Auberry, KJ ;
Moore, RJ ;
Angell, NH ;
Smith, RD ;
Springer, DL ;
Pounds, JG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (12) :947-955
[2]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[3]   Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA) [J].
Anderson, NL ;
Anderson, NG ;
Haines, LR ;
Hardie, DB ;
Olafson, RW ;
Pearson, TW .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (02) :235-244
[4]   The human plasma proteome - A nonredundant list developed by combination of four separate sources [J].
Anderson, NL ;
Polanski, M ;
Pieper, R ;
Gatlin, T ;
Tirumalai, RS ;
Conrads, TP ;
Veenstra, TD ;
Adkins, JN ;
Pounds, JG ;
Fagan, R ;
Lobley, A .
MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (04) :311-326
[5]   Capillary electrochromatography of peptides and proteins [J].
Bandilla, D ;
Skinner, CD .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :113-129
[6]   Surface modification in microchip electrophoresis [J].
Belder, D ;
Ludwig, M .
ELECTROPHORESIS, 2003, 24 (21) :3595-3606
[7]   Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma [J].
Deng, YZ ;
Zhang, NW ;
Henion, J .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1432-1439
[8]   Implications of new proteomics strategies for biology and medicine [J].
Domon, B ;
Broder, S .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (02) :253-260
[9]   Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry [J].
Figeys, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3721-3727
[10]   Protein profile of the HeLa cell line [J].
Fountoulakis, M ;
Tsangaris, G ;
Oh, JE ;
Maris, A ;
Lubec, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1038 (1-2) :247-265