VALIDITY OF PREOPERATIVE ULTRASOUND-GUIDED ASPIRATION IN THE REVISION OF HIP PROSTHESIS

被引:27
作者
Battaglia, Milva [1 ]
Vannini, Francesca [2 ]
Guaraldi, Federica [3 ]
Rossi, Giuseppe [4 ]
Biondi, Federico
Sudanese, Alessandra
机构
[1] Rizzoli Orthopaed Inst, Serv Ecog & Radiol, I-40136 Bologna, Italy
[2] Rizzoli Orthopaed Inst, Clin Orthopaed & Traumatol Unit 2, I-40136 Bologna, Italy
[3] Johns Hopkins Univ, Sch Med, Dept Pathol, Baltimore, MD 21205 USA
[4] Rizzoli Orthopaed Inst, Serv Intervent Radiol, I-40136 Bologna, Italy
关键词
Ultrasound-guided aspiration; Fluoroscopy-guided aspiration; Mobilized hip prosthesis; JOINT; INFECTION; DIAGNOSIS; ARTHROPLASTY;
D O I
10.1016/j.ultrasmedbio.2011.09.004
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Preoperative diagnosis of septic loosening hip prosthesis is often challenging. Culture test on joint samples obtained during revision surgery is the diagnostic gold standard while the role of preoperative hip aspiration is still controversial. The aims of this prospective randomized study were to compare the sensitivity, specificity and accuracy of preoperative ultrasound-guided and fluoroscopic-guided aspiration, and to identify associated laboratory parameters or scintigraphy that could help in predicting septic loosing hip prosthesis. Sixty patients affected by persistent pain after hip prosthesis randomly received fluoroscopic-guided or ultrasound-guided hip aspiration before revision surgery. The results of culture tests of joint fluid presurgically and at surgery were compared. In addition, associated blood inflammatory markers and scintigraphy were evaluated. Ultrasound-guided aspiration showed a better sensitivity (69% vs. 27%), specificity (94% vs. 75%) and accuracy (83% vs. 40%) than fluoroscopic-guided aspiration. The combination of ultrasound-guided aspiration and C-reactive protein represents the best model to predict septic loosening hip prosthesis preoperatively. (E-mail: milva.battaglia@ior.it) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1977 / 1983
页数:7
相关论文
共 18 条
[1]
Accuracy of joint aspiration for the preoperative diagnosis of infection in total hip arthroplasty [J].
Ali, F ;
Wilkinson, JM ;
Cooper, JR ;
Kerry, RM ;
Hamer, AJ ;
Norman, P ;
Stockley, I .
JOURNAL OF ARTHROPLASTY, 2006, 21 (02) :221-226
[2]
THE VALUE OF ASPIRATION OF THE HIP-JOINT BEFORE REVISION TOTAL HIP-ARTHROPLASTY [J].
BARRACK, RL ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :66-76
[3]
Diagnosis of periprosthetic infection [J].
Bauer, TW ;
Parvizi, J ;
Kobayashi, N ;
Krebs, V .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (04) :869-882
[4]
Risk factors for prosthetic joint infection: Case-control study [J].
Berbari, EF ;
Hanssen, AD ;
Duffy, MC ;
Steckelberg, JM ;
Ilstrup, DM ;
Harmsen, WS ;
Osmon, DR .
CLINICAL INFECTIOUS DISEASES, 1998, 27 (05) :1247-1254
[5]
Della Valle C, 2010, J AM ACAD ORTHOP SUR, V18, P760
[6]
Duffy PJ, 2005, J BONE JOINT SURG AM, V87A, P2566
[7]
Ultrasound for diagnosis of infection in revision total hip arthroplasty [J].
Eisler, T ;
Svensson, O ;
Engström, CF ;
Reinholt, FP ;
Lundberg, C ;
Wejkner, B ;
Schmalholz, A ;
Elmstedt, E .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :1010-1017
[8]
ULTRASOUND - GUIDED ASPIRATION IN SUSPECTED SEPSIS OF RESECTION ARTHROPLASTY OF THE HIP-JOINT [J].
FOLDES, K ;
BALINT, P ;
BALINT, G ;
BUCHANAN, WW .
CLINICAL RHEUMATOLOGY, 1995, 14 (03) :327-329
[9]
FORSTER IW, 1982, CLIN ORTHOP RELAT R, P48
[10]
WHITE CELL SCANS AND INFECTED JOINT REPLACEMENTS - FAILURE TO DETECT CHRONIC INFECTION [J].
GLITHERO, PR ;
GRIGORIS, P ;
HARDING, LK ;
HESSLEWOOD, SR ;
MCMINN, DJW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03) :371-374