Determination of zinc dialkyldithiocarbamates in latex condoms

被引:11
作者
Depree, GJ [1 ]
Bledsoe, TA [1 ]
Siegel, PD [1 ]
机构
[1] NIOSH, Analyt Serv Branch, Hlth Effects Lab Div, Morgantown, WV 26505 USA
关键词
D O I
10.1093/chromsci/42.2.80
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A simple high-performance liquid chromatographic (HPLC) assay is developed for measuring zinc dialkyldithiocarbamate (DTC) levels in latex condoms. After extraction of 14 different brands of latex condoms in acetonitrile, aliquots of the extracts are subjected to a preliminary screening assay by treatment with cobalt chloride and measurement of UV absorption at 320 nm, which results in the identification of 6 DTC-containing samples. Prior to analysis by HPLC, zinc dimethyldithiocarbamate (ZDMC) or zinc diethyldithiocarbamate (ZDEC) is added to the extracts in order to block transmetalation reactions with the analytes of interest. A reversed-phase C18 column, with gradient elution and UV detection at 260 nm, is used to measure the zinc DTCs. The limits of detection for ZDEC and zinc dibutyldithiocarbamate (ZDBC) are 5 and 10 μg/mL. Levels of ZDBC and ZDEC range from not detectable to 3.31 and 1.79 mg/condom, respectively. Total protein and latex allergenic protein levels are determined and range from 98 to 776 and 0.01 to 14.04 μg/unit, respectively, but are not related to the level of ZDBC or ZDEC. This methodology provides both screening and specific tools for the determination of unstable zinc DTC complexes in latex products.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 25 条
[1]
Ranking of allergenic potency of rubber chemicals in a modified local lymph node assay [J].
De Jong, WH ;
Van Och, FMM ;
Jager, CFD ;
Spiekstra, SW ;
Slob, W ;
Vandebriel, RJ ;
Van Loveren, H .
TOXICOLOGICAL SCIENCES, 2002, 66 (02) :226-232
[2]
Liquid chromatography of metal chelates. Chromatographic studies of homologous dialkyldithiocarbamates [J].
Dilli, S ;
Tong, P .
ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) :101-112
[3]
FURTHER-STUDIES OF DIETHYLDITHIOCARBAMATE COMPLEXES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DILLI, S ;
HADDAD, PR ;
HTOON, AK .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :313-328
[4]
Evaluation of percutaneous penetration of natural rubber latex proteins [J].
Hayes, BB ;
Afshari, A ;
Millecchia, L ;
Willard, PA ;
Povoski, SP ;
Meade, BJ .
TOXICOLOGICAL SCIENCES, 2000, 56 (02) :262-270
[5]
REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DIETHYLDITHIOCARBAMATE COMPLEXES USING RADIAL COMPRESSION COLUMNS [J].
HUTCHINS, SR ;
HADDAD, PR ;
DILLI, S .
JOURNAL OF CHROMATOGRAPHY, 1982, 252 (DEC) :185-192
[6]
EFFECT OF COLUMN TEMPERATURE ON SEPARATION AND DETERMINATION OF DITHIOCARBAMATE CHELATES BY REVERSED-PHASE HPLC [J].
ICHINOKI, S ;
YAMAZAKI, M ;
SUZUKI, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1992, 30 (06) :233-238
[7]
IDENTIFICATION OF CAUSATIVE CHEMICALS OF ALLERGIC CONTACT-DERMATITIS USING A COMBINATION OF PATCH TESTING IN PATIENTS AND CHEMICAL-ANALYSIS - APPLICATION TO CASES FROM INDUSTRIAL RUBBER PRODUCTS [J].
KANIWA, MA ;
ISAMA, K ;
NAKAMURA, A ;
KANTOH, H ;
ITOH, M ;
ICHIKAWA, M ;
HAYAKAWA, R .
CONTACT DERMATITIS, 1994, 30 (01) :20-25
[8]
IDENTIFICATION OF CAUSATIVE CHEMICALS OF ALLERGIC CONTACT-DERMATITIS USING A COMBINATION OF PATCH TESTING IN PATIENTS AND CHEMICAL-ANALYSIS - APPLICATION TO CASES FROM RUBBER GLOVES [J].
KANIWA, MA ;
ISAMA, K ;
NAKAMURA, A ;
KANTOH, H ;
HOSONO, K ;
ITOH, M ;
SHIBATA, K ;
USUDA, T ;
ASAHI, K ;
OSADA, T ;
MATSUNAGA, K ;
UEDA, H .
CONTACT DERMATITIS, 1994, 31 (02) :65-71
[9]
IDENTIFICATION OF CAUSATIVE CHEMICALS OF ALLERGIC CONTACT-DERMATITIS USING A COMBINATION OF PATCH TESTING IN PATIENTS AND CHEMICAL-ANALYSIS - APPLICATION TO CASES FROM RUBBER FOOTWEAR [J].
KANIWA, MA ;
ISAMA, K ;
NAKAMURA, A ;
KANTOH, H ;
ITOH, M ;
MIYOSHI, K ;
SAITO, S ;
SHONO, M .
CONTACT DERMATITIS, 1994, 30 (01) :26-34
[10]
HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC IDENTIFICATION AND DETERMINATION OF DITHIOCARBAMATES IN VULCANIZED RUBBER PRODUCTS [J].
KANIWA, MA .
JOURNAL OF CHROMATOGRAPHY, 1987, 405 :263-271