A new position sensing X-ray detector: Working principle and experimental results

被引:12
作者
Castoldi, A [1 ]
Guazzoni, C
机构
[1] Politecn Milan, Dip Ingn Nucl, I-20133 Milan, Italy
[2] Politecn Milan, Dip Elettron & Informaz, I-20133 Milan, Italy
关键词
charge transfer; image sensors; X-ray detectors; X-ray imaging; X-ray spectroscopy detectors;
D O I
10.1109/16.740898
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The working principle and the first experimental characterization of a new fully depleted X-ray detector, called controlled-drift detector (CDD),(1) are presented, The detector is operated in integrate-readout mode. During the integration phase the signal electrons generated by the incident X-ray are stored in suitably engineered potential wells, During the readout phase the potential wells are removed and replaced by a uniform drift field that transports the signal electrons to the readout electrode. The drift time gives the position of incidence. Full depletion of the detector wafer allows for high X-ray efficiency and for backward illumination, The first experimental measurements demonstrate the fast readout of the integrated signal electrons achievable with a static drift field. At a drift field of 300 V/cm the measured readout speed is 0.35 cm/mu s. The expected charge handling capacity is 10(5)-10(6) electrons per pixel. The new detector provides unambiguous two-dimensional (2-D) position measurement with readout times of the order of 10 mu s.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 8 条
[1]   Signal charge sharing in multilinear drift detectors: Design and experimental characterization [J].
Castoldi, A ;
Rehak, P ;
Holl, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (02) :134-141
[2]   A new high resolution X-ray imaging detector with fast read-out [J].
Castoldi, A ;
Gatti, E ;
Guazzoni, C ;
Longoni, A ;
Rehak, P ;
Struder, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :379-381
[3]   Conception and design criteria of a novel silicon device for the measurement of position and energy of X rays [J].
Castoldi, A ;
Guazzoni, C ;
Longoni, A ;
Gatti, E ;
Rehak, P ;
Struder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (05) :1724-1732
[4]   A new silicon drift detector with reduced lateral diffusion [J].
Castoldi, A ;
Rehak, P ;
Holl, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :375-380
[5]   DOUBLE PARTICLE RESOLUTION IN SEMICONDUCTOR DRIFT DETECTORS [J].
GATTI, E ;
REHAK, P ;
SAMPIETRO, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (03) :469-476
[6]   RESISTIVE GATE CTD AREA-IMAGE SENSOR [J].
HEYNS, H ;
VANSANTEN, JG .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1978, 13 (01) :61-65
[7]   Performance of the pn-CCD X-ray detector system designed for the XMM satellite mission [J].
Soltau, H ;
Holl, P ;
Kemmer, J ;
Krisch, S ;
vonZanthier, C ;
Hauff, D ;
Richter, R ;
Brauninger, H ;
Hartmann, R ;
Hartner, G ;
Krause, N ;
Meidinger, N ;
Pfeffermann, E ;
Reppin, C ;
Schwaab, G ;
Struder, L ;
Trumper, J ;
Kendziorra, E ;
Kramer, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :340-345
[8]   THE MPI AIT X-RAY IMAGER (MAXI) - HIGH-SPEED PN CCDS FOR X-RAY-DETECTION [J].
STRUDER, L ;
BRAUNINGER, H ;
MEIER, M ;
PREDEHL, P ;
REPPIN, C ;
STERZIK, M ;
TRUMPER, J ;
CATTANEO, P ;
HAUFF, D ;
LUTZ, G ;
SCHUSTER, KF ;
SCHWARZ, A ;
KENZIORRA, E ;
STAUBERT, A ;
GATTI, E ;
LONGONI, A ;
SAMPIETRO, M ;
RADEKA, V ;
REHAK, P ;
RESCIA, S ;
MANFREDI, PF ;
BUTTLER, W ;
HOLL, P ;
KEMMER, J ;
PRECHTEL, U ;
ZIEMANN, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :227-235