A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time

被引:25
作者
Thekkudan, Dennis F. [1 ]
Rutan, Sarah C. [1 ]
Carr, Peter W. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
基金
美国国家卫生研究院;
关键词
Comprehensive two-dimensional liquid chromatography; Area estimation; Gaussian; Nonlinear fitting algorithm; Moments; Peak volume; Quantification precision and accuracy; FLIGHT MASS-SPECTROMETRY; GC X GC; GAS-CHROMATOGRAPHY; QUANTITATIVE-ANALYSIS; MODULATION; 1ST-DIMENSION; SEPARATIONS; CAPACITY; REPRODUCIBILITY; RESOLUTION;
D O I
10.1016/j.chroma.2010.04.039
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Simulated chromatographic data were used to determine the precision and accuracy in the estimation of peak volumes (i.e., peak sizes) in comprehensive two-dimensional liquid chromatography in time (LC x LC). Peak volumes were determined both by summing the areas in the second dimension chromatograms and by fitting the second dimension areas to a Gaussian peak. The Gaussian method is better at predicting the peak volume than the moments method provided there are at least three second dimension injections above the limit of detection (LOD). However, when only two of the second dimension signals are substantially above baseline, the accuracy and precision of the Gaussian fit method become quite poor because the results from the fitting algorithm become indeterminate. Based on simulations in which the modulation ratio (M-R = 4(1) sigma/t(s)) and sampling phase (phi) were varied, we conclude for well-resolved peaks that the optimum precision in peak volumes in 2D separations will be obtained when the M-R is between two and five, such that there are typically four to ten second dimension peaks recorded over the eight sigma width of the first dimension peak. This sampling rate is similar to that suggested by the Murphy-Schure-Foley criterion. This provides an RSD of approximately 2% for the signal-to-noise ratio used in the present simulations. The precision of the peak volume of experimental data was also assessed, and RSD values were in the range of 4-5%. We conclude that the poorer precision found in the LC x LC experimental data as compared to LC may be clue to experimental imprecision in sampling the effluent from the first dimension column. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:4313 / 4327
页数:15
相关论文
共 55 条
[1]
Peak Modeling Approach to Accurate Assignment of First-Dimension Retention Times in Comprehensive Two-Dimensional Chromatography [J].
Adcock, Jacqui L. ;
Adams, Mike ;
Mitrevski, Blagoj S. ;
Marriott, Philip J. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :6797-6804
[2]
Comprehensive two-dimensional liquid chromatography separations of pharmaceutical samples using dual Fused-Core columns in the 2nd dimension [J].
Alexander, Anthony J. ;
Ma, Lianjia .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) :1338-1345
[3]
ANTIA FD, 1988, J CHROMATOGR, V435, P1
[4]
Accumulating resampling (modulation) in comprehensive two-dimensional capillary GC (GC x GC) [J].
Blumberg, Leonid M. .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (19) :3358-3365
[5]
AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[6]
Evaluation of comprehensive two-dimensional gas chromatography - time-of-flight mass spectrometry for the determination of pesticides in tobacco [J].
Cochran, Jack .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) :202-210
[7]
Dependence of Effective Peak Capacity in Comprehensive Two-Dimensional Separations on the Distribution of Peak Capacity between the Two Dimensions [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8122-8134
[8]
Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473
[9]
Quantitation of suspected allergens in fragrances Part II. Evaluation of comprehensive gas chromatography-conventional mass spectrometry [J].
Debonneville, C ;
Chaintreau, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1027 (1-2) :109-115
[10]
DUGO P, 2009, ANAL CHEM, V1216, P7483