Accumulating resampling (modulation) in comprehensive two-dimensional capillary GC (GC x GC)

被引:36
作者
Blumberg, Leonid M. [1 ]
机构
[1] Fast GC Consulting, Wilmington, DE 19801 USA
关键词
Accumulating resampling; Optimal sampling density; Resampling; Sampling density;
D O I
10.1002/jssc.200800424
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During each sampling period, an accumulating resampler (modulator) in comprehensive 2-D chromatography accumulates all eluite from the first-dimension column and reinjects the whole or a portion of the accumulated material into the second-dimension column. The detrimental effect of the resampling on peak capacity of a 2-D separation comes from the broadening of the peaks along the first-dimension due to the resampling itself and due to the subsequent peak reconstruction. Sampling density (rho(S)) of resampling is the number of sampling periods per standard deviation of a peak at the outlet of the first-dimension column. It is shown that a simple formula describes the peak broadening as a function of rho(S) at any (even practically too low or too high) rho(S), for the peaks of any (not necessarily Gaussian) shape, for a wide class of peak reconstruction techniques, and for any 2-D separation (GC x GC, LC x LC, etc.). In capillary GC x GC, optimal rho(S) (rho(S,Opt)) depends on the type of the peak reconstruction and on the degree of the gas decompression along the second-dimension column. When reconstructing using linear interpolation, rho(S,Opt) = 0.7 at large and rho(S,Opt) = 0.5 at small gas decompression. The choice of exact optimal conditions is not critical. Thus, two-fold departure of actual rho(S) from rho(S,Opt) in either direction (under- or oversampling) causes only 10% drop in the net peak capacity of GC x GC. The quantitative effect of a much greater undersampling is also evaluated.
引用
收藏
页码:3358 / 3365
页数:8
相关论文
共 19 条
[1]   Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography [J].
Blumberg, Leonid M. ;
David, Frank ;
Klee, Matthew S. ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (01) :2-16
[2]   Comprehensive two-dimensional gas chromatography: metrics, potentials, limits [J].
Blumberg, LM .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :29-38
[3]  
Blumberg LM, 2000, J MICROCOLUMN SEP, V12, P508, DOI 10.1002/1520-667X(2000)12:9<508::AID-MCS5>3.0.CO
[4]  
2-Y
[5]   Method translation and retention time locking in partition GC [J].
Blumberg, LM ;
Klee, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3828-3839
[6]  
Blumberg LM, 1999, HRC-J HIGH RES CHROM, V22, P403
[7]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[8]  
Crochiere R. E., 1983, MULTIRATE DIGITAL SI
[9]   STATISTICAL-THEORY OF SPOT OVERLAP IN 2-DIMENSIONAL SEPARATIONS [J].
DAVIS, JM .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2141-2152
[10]   Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473