Design and development strategy for the rotary blood pump

被引:54
作者
Nose, Y [1 ]
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
关键词
development strategy of blood pump; rotary blood pump; axial flow pump; centrifugal blood pump; 2 day pump; 2 week pump; permanent pump;
D O I
10.1046/j.1525-1594.1998.06098.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Development of an antitraumatic antithrombogenic and durable blood pump is a very difficult task. Based upon this author's experience of over 35 years in the development of various types of cardiac prostheses, development strategies for a rotary blood pump are described. A step-by-step development strategy is thus proposed. Initially, the development of a 2 day antitraumatic pump (Phase 1) would be made. Then, conversion of this pump to a 2 week antithrombogenic pump (Phase 2) should be attempted. After the successful development of the Phase 2 pump, the conversion of this device to a durable, implantable, and long-term blood pump (Phase 3) should be established. Based upon this development strategy, 2 rotary blood pumps, namely, the axial Row blood pump and the centrifugal blood pump, have been developed in less than 4 pears with modest development costs.
引用
收藏
页码:438 / 446
页数:9
相关论文
共 13 条
[1]   Improved left ventricular function after chronic left ventricular unloading [J].
Frazier, OH ;
Benedict, CR ;
Radovancevic, B ;
Bick, RJ ;
Capek, P ;
Springer, WE ;
Macris, MP ;
Delgado, R ;
Buja, LM .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :675-681
[2]   Ex vivo evaluation of the NASA/DeBakey axial flow ventricular assist device - Results of a 2 week screening test [J].
Kawahito, K ;
Benkowski, R ;
Otsubo, S ;
Rosenbaum, B ;
Moreland, R ;
Noon, GP ;
Nose, Y ;
DeBakey, ME .
ASAIO JOURNAL, 1996, 42 (05) :M754-M757
[3]   LDL-apheresis atherosclerosis regression study (LAARS) - Effect of aggressive versus conventional lipid lowering treatment on coronary atherosclerosis [J].
Kroon, AA ;
Aengevaeren, WRM ;
vanderWerf, T ;
Uijen, GJH ;
Reiber, JHC ;
Bruschke, AVG ;
Stalenhoef, AFH .
CIRCULATION, 1996, 93 (10) :1826-1835
[4]   Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump [J].
Makinouchi, K ;
Nakazawa, T ;
Takami, Y ;
Takatani, S ;
Nose, Y .
ARTIFICIAL ORGANS, 1996, 20 (06) :523-528
[5]   Low-density lipoprotein removal methods by membranes and future perspectives [J].
Matsuda, Y ;
Malchesky, PS ;
Nose, Y .
ARTIFICIAL ORGANS, 1996, 20 (04) :346-354
[6]   Development and initial testing of a permanently implantable centrifugal pump [J].
Nakazawa, T ;
Takami, Y ;
Benkowski, R ;
Ohtsubo, S ;
Yukio, O ;
Tayama, E ;
Ohtsuka, G ;
Niimi, Y ;
Glueck, J ;
Sueoka, A ;
Schmallegger, H ;
Schima, H ;
Wolner, E ;
Nose, Y .
ARTIFICIAL ORGANS, 1997, 21 (07) :597-601
[7]  
Nose Y, 1997, ARTIF ORGANS, V21, P263
[8]   MY LIFE WITH THE NATIONAL-INSTITUTES-OF-HEALTH ARTIFICIAL-HEART PROGRAM [J].
NOSE, Y .
ARTIFICIAL ORGANS, 1990, 14 (03) :174-190
[9]   Therapeutic and physiological artificial heart: Future prospects [J].
Nose, Y ;
Ohtsubo, S ;
Tayama, E .
ARTIFICIAL ORGANS, 1997, 21 (07) :592-596
[10]  
NOSE Y, 1993, ASAIO J, pM160