Piezoelectric quartz crystal biosensors

被引:234
作者
Bunde, RL [1 ]
Jarvi, EJ
Rosentreter, JJ
机构
[1] Idaho State Univ, Dept Pharmaceut Sci, Pocatello, ID 83209 USA
[2] Idaho State Univ, Dept Chem, Pocatello, ID 83209 USA
关键词
review; piezoelectric quartz crystal; biosensor;
D O I
10.1016/S0039-9140(97)00392-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensing methods utilize the intrinsic selectivity of a biorecognition process to create relatively simple, low cost, analytical alternatives for a variety of research investigations. Here, biosensor applications of the piezoelectric quartz crystal (PQC) are reviewed. The discussion is divided into sections focusing on the development of PQC based analytical techniques, applications in solution phase sensing pertaining to PQC biosensors, and the current state of knowledge in PQC biosensing applications. Immobilization procedures, dip and dry assay techniques, and solution phase sensing methods are considered in detail. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1223 / 1236
页数:14
相关论文
共 106 条
[21]   4-LAYER THEORY FOR THE ACOUSTIC SHEAR-WAVE SENSOR IN LIQUIDS INCORPORATING INTERFACIAL SLIP AND LIQUID STRUCTURE [J].
DUNCANHEWITT, WC ;
THOMPSON, M .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :94-105
[22]   PIEZOELECTRIC CELL-GROWTH SENSOR [J].
EBERSOLE, RC ;
FOSS, RP ;
WARD, MD .
BIO-TECHNOLOGY, 1991, 9 (05) :450-454
[23]   SPONTANEOUSLY FORMED FUNCTIONALLY ACTIVE AVIDIN MONOLAYERS ON METAL-SURFACES - A STRATEGY FOR IMMOBILIZING BIOLOGICAL REAGENTS AND DESIGN OF PIEZOELECTRIC BIOSENSORS [J].
EBERSOLE, RC ;
MILLER, JA ;
MORAN, JR ;
WARD, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (08) :3239-3241
[24]   AMPLIFIED MASS IMMUNOSORBENT-ASSAY WITH A QUARTZ CRYSTAL MICROBALANCE [J].
EBERSOLE, RC ;
WARD, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (26) :8623-8628
[25]  
FAWCETT NC, 1988, ANAL LETT, V21, P1099
[26]  
FENGJIAO H, 1994, ANAL LETT, V27, P655
[27]   LATEX PIEZOELECTRIC IMMUNOASSAY - EFFECT OF INTERFACIAL PROPERTIES [J].
GHOURCHIAN, HO ;
KAMO, N .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :99-105
[28]   IMPROVEMENT OF ALTEX PIEZOELECTRIC IMMUNOASSAY - DETECTION OF RHEUMATOID-FACTOR [J].
GHOURCHIAN, HO ;
KAMO, N ;
HOSOKAWA, T ;
AKITAYA, T .
TALANTA, 1994, 41 (03) :401-406
[29]   DETECTION OF GALACTOSYLTRANSFERASE USING CHEMICALLY MODIFIED PIEZOELECTRIC QUARTZ [J].
GRANDE, LH ;
GEREN, CR ;
PAUL, DW .
SENSORS AND ACTUATORS, 1988, 14 (04) :387-403
[30]   REAL-TIME MEASUREMENT OF ANCHORAGE-DEPENDENT CELL-ADHESION USING A QUARTZ CRYSTAL MICROBALANCE [J].
GRYTE, DM ;
WARD, MD ;
HU, WS .
BIOTECHNOLOGY PROGRESS, 1993, 9 (01) :105-108