Perfluorosulfonated ionomer-modified polyethylene.: A material for simultaneous solid-phase enrichment and enhanced precolumn dansylation of C-21 ketosteroids in human serum

被引:4
作者
Appelblad, P
Ahmed, A
Pontén, E
Bäckström, T
Irgum, K [1 ]
机构
[1] Umea Univ, Dept Chem, S-90187 Umea, Sweden
[2] Umea Univ Hosp, Dept Clin Sci, S-90185 Umea, Sweden
关键词
D O I
10.1021/ac010071w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new derivatization procedure has been developed where solid-phase catalysis is utilized to facilitate the formation of hydrazones in precolumn labeling of keto-containing compounds. This procedure has been implemented on a solid-phase enrichment and enhanced derivatization (SPEED) device, prepared from porous polyethylene that has been coated with Nafion and dansylhydrazine. The SPEED devices have been optimized using experimental design and characterized for dansylation of C-21 ketosteroids by multivariate data analysis, using progesterone as the model compound. The reaction temperature and the molar ratio between the steroid and the derivatization reagent were found to be the factors most strongly affecting the reaction. Faster reaction kinetics were achieved when the molar ratio between dansylhydrazine and the steroid was increased. Mass spectroscopic analysis showed that the four derivative peaks eluting when derivatized progesterone was separated on an octadecyl silica stationary phase were due to the syn and anti mono- and bis- (hydrazones) formed in the reaction. Using optimal reaction conditions, the derivatives mainly constitute the syn and anti conformers of bis-derivatives. In contrast to solution-based acid catalysis, the SPEED device was remarkably insensitive to water in the reaction mixture. A sample volume of 400 muL was found to be the maximum, enabling sample enrichment prior derivatization. Using optimal experimental conditions, picomole amounts of ketosteroids could be derivatized in 10 min at room temperature. Analysis of spiked serum samples containing 0.4-2.0 nmol of progesterone showed overall recoveries of 52-63%. The corresponding 3 sigma detection limit was 1.3 pmol (n = 4, 100 muL injected), as estimated from calibration curve data.
引用
收藏
页码:3701 / 3708
页数:8
相关论文
共 19 条
[1]   Derivatization of steroids with dansylhydrazine using trifluoromethanesulfonic acid as catalyst [J].
Appelblad, P ;
Ponten, E ;
Jaegfeldt, LH ;
Backstrom, T ;
Irgum, K .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4905-4911
[2]   Determination of C-21 ketosteroids in serum using trifluoromethanesulfonic acid catalyzed precolumn dansylation and 1,1′-oxalyldiimidazole postcolumn peroxyoxalate chemiluminescence detection [J].
Appelblad, P ;
Jonsson, T ;
Bäckström, T ;
Irgum, K .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5002-5009
[3]   Neurosteroids: A novel function of the brain [J].
Baulieu, EE .
PSYCHONEUROENDOCRINOLOGY, 1998, 23 (08) :963-987
[4]   NEUROSTEROIDS - A NEW BRAIN-FUNCTION [J].
BAULIEU, EE ;
ROBEL, P .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1990, 37 (03) :395-403
[5]   FLUOROMETRIC HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROCORTISONE IN HUMAN-PLASMA [J].
GOEHL, TJ ;
SUNDARESAN, GM ;
PRASAD, VK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1979, 68 (11) :1374-1376
[6]  
GROT WG, 1984, Patent No. 4433082
[7]   On-line derivatization into precolumns for the determination of drugs by liquid chromatography and column switching: Determination of amphetamines in urine [J].
HerraezHernandez, R ;
CampinsFalco, P ;
SevillanoCabeza, A .
ANALYTICAL CHEMISTRY, 1996, 68 (05) :734-739
[8]   SENSITIVE ASSAY SYSTEM FOR BILE-ACIDS AND STEROIDS HAVING HYDROXYL-GROUPS UTILIZING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HIGASHIDATE, S ;
HIBI, K ;
SENDA, M ;
KANDA, S ;
IMAI, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 515 :577-584
[9]   TRIFLUOROMETHANESULFONIC ACID AND DERIVATIVES [J].
HOWELLS, RD ;
MCCOWN, JD .
CHEMICAL REVIEWS, 1977, 77 (01) :69-92
[10]   Trifluoromethanesulfonic acid as a catalyst for the formation of dansylhydrazone derivatives [J].
Hyytiainen, M ;
Appelblad, P ;
Ponten, E ;
Stigbrand, M ;
Irgum, K ;
Jaegfeldt, H .
JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (02) :279-283