Measurements with Si and GaAs pixel detectors bonded to photon counting readout chips

被引:16
作者
Schwarz, C
Campbell, M
Goeppert, R
Ludwig, J
Mikulec, B
Runge, K
Smith, KM
Snoeys, W
机构
[1] Univ Freiburg, Fak Phys, D-79104 Freiburg, Germany
[2] CERN, Geneva, Switzerland
[3] Univ Glasgow, Dept Phys & Astron, Glasgow, Lanark, Scotland
关键词
medical imaging; GaAs; silicon; hybrid pixel detector; X-rays; photon counting chip; MTF;
D O I
10.1016/S0168-9002(01)00829-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Detectors fabricated with SI-GaAs and Si bulk material were bonded to Photon Counting Chips (PCC), developed in the framework of the MEDIPIX Collaboration. The PCC consists of a matrix of 64 x 64 identical square pixels (170 mum x 170 mum) with a 15-bit counter in each cell. We investigated the imaging properties of these detector systems under exposure of a dental X-ray tube at room temperature. The image homogeneity and the mean count rate were determined via hood exposure images and compared. Exposures for GaAs detectors exhibit a 3 times larger spread in count rate per image in comparison to Si detectors. This also results in a 3 times worse signal to noise ratio. IV-characteristics and X-ray images at different values of the detectors bias voltage were also taken and show a 30 times higher leakage current for GaAs, The Si detector is fully active beginning from 70 V, whereas the GaAs detector does not reach full charge collection. The presampling modulation transfer function of both assembly types was measured via slit images and gives a spatial resolution of 4.3 lp/mm for both detector systems. (C) 2001 Elsevier Science B,V. All rights reserved.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 12 条
[1]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[2]   Analysis of the active layer in SI GaAs Schottky diodes [J].
Castaldini, A ;
Cavallini, A ;
Polenta, L ;
Canali, C ;
Nava, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01) :79-84
[3]   X-ray imaging using a 320 x 240 hybrid GaAs pixel detector [J].
Irsigler, R ;
Andersson, J ;
Alverbro, J ;
Borglind, J ;
Fröjdh, C ;
Helander, P ;
Manolopoulos, S ;
Martijn, H ;
O'Shea, V ;
Smith, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :507-512
[4]   Comparison of hybrid pixel detectors with Si and GaAs sensors [J].
Lindner, M ;
Fischer, P ;
Florin, S ;
Göppert, R ;
Hausmann, J ;
Ludwig, J ;
Runge, K ;
Schwarz, C ;
Söldner-Rembold, A ;
Wermes, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01) :63-73
[5]   Characterisation of a single photon counting pixel system for imaging of low-contrast objects [J].
Mikulec, B ;
Campbell, M ;
Dipasquale, G ;
Schwarz, C ;
Watt, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :352-359
[6]   Characterisation of a single photon counting pixel detector [J].
Passmore, MS ;
Bates, R ;
Mathieson, K ;
O'Shea, V ;
Rahman, M ;
Seller, P ;
Smith, KM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01) :202-208
[7]   Formation of a quasi-neutral region in Schottky diodes based on semi-insulating GaAs and the influence of the compensation mechanism on the particle detector performance [J].
Rogalla, M ;
Runge, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01) :44-56
[8]  
ROGALLA M, 1998, THESIS AACHEN
[9]   Dose-dependent X-ray measurements using a 64x64 hybrid GaAs pixel detector with photon counting [J].
Schwarz, C ;
Campbell, M ;
Goeppert, R ;
Ludwig, J ;
Mikulec, B ;
Rogalla, M ;
Runge, K ;
Soeldner-Rembold, A ;
Smith, KM ;
Snoeys, W ;
Watt, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01) :91-96
[10]   RESOLUTION AS DEFINED BY LINE SPREAD AND MODULATION TRANSFER-FUNCTIONS FOR 4 DIGITAL INTRAORAL RADIOGRAPHIC SYSTEMS [J].
WELANDER, U ;
MCDAVID, WD ;
SANDERINK, GCH ;
TRONJE, G ;
MORNER, AC ;
DOVE, B .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (01) :109-115