Detection of daunomycin using phosphatidylserine and aptamer co-immobilized on Au nanoparticles deposited conducting polymer

被引:115
作者
Chandra, Pranjal [1 ,2 ]
Noh, Hui-Bog [1 ,2 ]
Won, Mi-Sook [3 ]
Shim, Yoon-Bo [1 ,2 ]
机构
[1] Pusan Natl Univ, Dept Chem, Pusan 609735, South Korea
[2] Pusan Natl Univ, Inst BioPhysico Sensor Technol, Pusan 609735, South Korea
[3] Korea Basic Sci Inst, Busan Ctr, Pusan 609735, South Korea
关键词
Daunomycin sensor; Phosphatidylserine; Aptamer; Au nanoparticles; Conducting polymer; ELECTROCHEMICAL DETECTION; CARBON NANOTUBES; DNA; DRUG; DAUNORUBICIN; ELECTROPHORESIS; ANTHRACYCLINES; SPECIFICITY; DOXORUBICIN; RNA;
D O I
10.1016/j.bios.2011.04.060
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A highly sensitive and selective sensor for daunomycin was developed using phosphatidylserine (PS) and aptamer as bioreceptors. The PS and aptamer were co-immobilized onto gold nanoparticles modified/functionalized [2,2':5',2 ''-terthiophene-3'-(p-benzoic acid)] (polyTTBA) conducting polymer. Direct electrochemistry of daunomycin was used to fabricate a label free sensor that monitors current at -0.61 V. The formation of each layer was confirmed with XPS, SEM, and QCM. Response of the sensor was compared with and without PS in terms of sensitivity and selectivity. Interaction between the sensor probe and daunomycin was determined with DPV. The experimental parameters affecting sensor performance were optimized in terms of concentration of immobilized aptamer, PS:aptamer ratio, temperature, pH, and reaction times. The dynamic range for daunomycin analysis ranged between 0.1 and 60.0 nM with a detection limit of 52.3 +/- 2.1 pM. Sensor was also examined for interference effect of other drugs. The present sensor exhibited long term stability and successfully detected daunomycin in a real human urine spiked with daunomycin. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4442 / 4449
页数:8
相关论文
共 38 条
[1]   Direct Electrochemistry of Cholesterol Oxidase Immobilized on a Conducting Polymer: Application for a Cholesterol Biosensor [J].
Abdelwahab, Adel A. ;
Won, Mi-Sook ;
Shim, Yoon-Bo .
ELECTROANALYSIS, 2010, 22 (01) :21-25
[2]  
ALBERTS DS, 1971, CLIN PHARMACOL THER, V12, P96
[3]  
Alexy R., 2003, ANTIBIOTICS AQUATIC
[4]   Voltammetric studies of the interaction of daunomycin anticancer drug with DNA and analytical applications [J].
Chu, X ;
Shen, GL ;
Jiang, JH ;
Kang, TF ;
Xiong, B ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 1998, 373 (01) :29-38
[5]   REMISSION INDUCTION WITH DAUNOMYCIN, VINCRISTINE, AND PREDNISONE IN ADULT ACUTE LYMPHOCYTIC-LEUKEMIA [J].
EINHORN, LH ;
BOND, WH .
ONCOLOGY, 1977, 34 (01) :25-28
[6]   Dendrimer modified graphite sensors for detection of anticancer drug Daunorubicin by voltammetry and electrochemical impedance spectroscopy [J].
Erdem, Arzum ;
Karadeniz, Hakan ;
Caliskan, Ayfer .
ANALYST, 2011, 136 (05) :1041-1045
[7]   DISRUPTION OF CELLULAR SIGNALING PATHWAYS BY DAUNOMYCIN THROUGH DESTABILIZATION OF NONLAMELLAR MEMBRANE STRUCTURES [J].
ESCRIBA, PV ;
SASTRE, M ;
GARCIASEVILLA, JA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (16) :7595-7599
[8]   ROLE OF MEMBRANE-LIPIDS IN THE INTERACTION OF DAUNOMYCIN WITH PLASMA-MEMBRANES FROM TUMOR-CELLS - IMPLICATIONS IN DRUG-RESISTANCE PHENOMENA [J].
ESCRIBA, PV ;
FERRERMONTIEL, AV ;
FERRAGUT, JA ;
GONZALEZROS, JM .
BIOCHEMISTRY, 1990, 29 (31) :7275-7282
[9]  
FACCHINETTI T, 1978, CANCER RES, V38, P3944
[10]   An RNA aptamer-based electrochemical biosensor for detection of theophylline in serum [J].
Ferapontova, Elena E. ;
Olsen, Eva M. ;
Gothelf, Kurt V. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (13) :4256-+