Nerve regeneration across a 2-cm gap in the rat median nerve using a resorbable nerve conduit filled with Schwann cells

被引:108
作者
Sinis, N
Schaller, HE
Schulte-Eversum, C
Schlosshauer, B
Doser, M
Dietz, K
Rösner, H
Müller, HW
Haerle, M
机构
[1] Univ Tubingen, Klin Hand Plast Rekonstrukt & Verbrennungschirurg, Berufsgenossenschaftliche Unfallklin, D-72076 Tubingen, Germany
[2] Univ Dusseldorf, Neurol Klin, Mol Neurobiol Lab, D-4000 Dusseldorf, Germany
[3] Univ Tubingen, Nat Wissensch Liches & Med Inst, Reutlingen, Germany
[4] Deutsch Zentrum Biomat & Organersatz, Denkendorf, Germany
[5] Univ Hohenheim, Inst Zool Zell & Entwicklungsneurobiol, D-7000 Stuttgart, Germany
[6] Univ Tubingen, Inst Med Biometrie, D-72074 Tubingen, Germany
关键词
epsilon-caprolactone; nerve repair; nerve conduit; median nerve; Schwann cell; rat;
D O I
10.3171/jns.2005.103.6.1067
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. In a rat model, nerve regeneration was evaluated across a 2-cm defect in the median nerve by using a resorbable artificial nerve conduit. The aim of this study was to develop an artificial, biocompatible nerve guide to induce regeneration in the peripheral nervous system. Methods. The authors compared a nerve conduit of triinethylenecarbonate-co-epsilon-caprolactone (TMC/CL) filled with autologous Schwann cells with both an empty hollow conduit and an autologous nerve graft. Animals that did not undergo surgery served as the control group. Nerve regeneration was evaluated with the grasping test, histological analysis of the nerve, muscle weight analysis (flexor digitorum superficialis muscle), and electrophysiological examination. After an observation period of 9 months, regeneration occurred only in animals that had received an autologous graft or a Schwann cell containing nerve conduit. No signs of regeneration were found in animals supplied with the empty conduit. Conclusions. Results of this study reveal the important role of Schwann cells in the regeneration process across a 2-cm defect in the rat median nerve. Furthermore, Schwann cell-filled nerve conduits induced functional recovery, as demonstrated in the grasping test, that was comparable with that of the autologous graft 9 months after implantation.
引用
收藏
页码:1067 / 1076
页数:10
相关论文
共 49 条
[1]
Allan CH, 2000, HAND CLIN, V16, P67
[2]
ARCHIBALD SJ, 1995, J NEUROSCI, V15, P4109
[3]
THE INFLUENCE OF FIBRONECTIN AND LAMININ DURING SCHWANN-CELL MIGRATION AND PERIPHERAL-NERVE REGENERATION THROUGH SILICON CHAMBERS [J].
BAILEY, SB ;
EICHLER, ME ;
VILLADIEGO, A ;
RICH, KM .
JOURNAL OF NEUROCYTOLOGY, 1993, 22 (03) :176-184
[4]
Barrows T., 1986, CLIN MATER, V1, P233, DOI [DOI 10.1016/S0267-6605(86)80015-4, 10.1016/S0267-6605(86)80015-4]
[5]
Nerve repair by means of tubulization: Literature review and personal clinical experience comparing biological and synthetic conduits for sensory nerve repair [J].
Battiston, B ;
Geuna, S ;
Ferrero, M ;
Tos, P .
MICROSURGERY, 2005, 25 (04) :258-267
[6]
THE GRASPING TEST - A SIMPLE BEHAVIORAL-METHOD FOR OBJECTIVE QUANTITATIVE ASSESSMENT OF PERIPHERAL-NERVE REGENERATION IN THE RAT [J].
BERTELLI, JA ;
MIRA, JC .
JOURNAL OF NEUROSCIENCE METHODS, 1995, 58 (1-2) :151-155
[7]
BRIDGING NERVE DEFECTS WITH COMBINED SKELETAL-MUSCLE AND VEIN CONDUITS [J].
BRUNELLI, GA ;
BATTISTON, B ;
VIGASIO, A ;
BRUNELLI, G ;
MAROCOLO, D .
MICROSURGERY, 1993, 14 (04) :247-251
[8]
SELECTIVE REINNERVATION OF DISTAL MOTOR STUMPS BY PERIPHERAL MOTOR AXONS [J].
BRUSHART, TME ;
SEILER, WA .
EXPERIMENTAL NEUROLOGY, 1987, 97 (02) :289-300
[9]
CHIU DTW, 1982, SURGERY, V91, P226
[10]
AUTOLOGOUS DENATURED MUSCLE AS A NERVE GRAFT [J].
DEFRANZO, AJ ;
MORYKWAS, MJ ;
LAROSSE, JR ;
JENNINGS, DA ;
CHALLA, V ;
ARGENTA, LC .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1994, 10 (03) :145-149