Improved accuracy and precision of gas chromatography mass spectrometry measurements for metabolic tracers

被引:69
作者
Patterson, BW [1 ]
Zhao, GH [1 ]
Klein, S [1 ]
机构
[1] Washington Univ, Sch Med, Dept Internal Med, Div Gastroenterol, St Louis, MO 63110 USA
来源
METABOLISM-CLINICAL AND EXPERIMENTAL | 1998年 / 47卷 / 06期
关键词
D O I
10.1016/S0026-0495(98)90035-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of stable-isotope tracer methodology to study substrate metabolic kinetics requires accurate measurement of the tracer to tracee ratio (TTR), often by gas chromatography/mass spectrometry (GC/MS). Many approaches for measurement of the TTR by GC/MS do not use standards of known isotopic enrichment to control for variability in instrument response. In addition, most GC/MS applications exhibit some degree of concentration dependency whereby the measured ion abundance ratio varies with the quantity of sample analyzed, thereby placing a limitation on the accuracy of isotopic enrichment standard curves unless the quantities of standards and samples analyzed are closely matched. We document the degree to which day-to-day variability can affect the instrument response for several GC/MS analyses of metabolic tracers when isotopic enrichment standards are not used to control for variable instrument response. Furthermore, we report a new approach that incorporates concentration dependencies within a standard curve to improve the accuracy and precision of TTR measurements over a range of sample quantities analyzed. The new approach was applied to plasma samples obtained from experimental protocols performed in human subjects with three commonly used tracers: H-2(2)-palmitate, N-15(2)-urea, and C-13-leucine. Variability in the day-to-day instrument response was 84% and 26% for H-2(2)-palmitate and N-15(2)-urea, respectively; in addition, up to 10% variability due to concentration dependency was noted for these applications, The new approach virtually eliminated these sources of variability. After controlling for concentration dependency, a threefold reduction in the standard error was noted when the enrichment of C-13-leucine measured by electron-impact (El) ionization GC/MS was correlated against negative chemical ionization (NCI) GC/MS. These data demonstrate that our new approach decreases the errors in TTR determination caused by variations in instrument response and concentration dependency. This approach is generically applicable, and can improve the accuracy and precision of TTR determinations for most GC/MS analyses. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:706 / 712
页数:7
相关论文
共 20 条
[1]   ANALYSIS OF LINEAR APPROACHES TO QUANTITATIVE STABLE ISOTOPE METHODOLOGY IN MASS-SPECTROMETRY [J].
BUSH, ED ;
TRAGER, WF .
BIOMEDICAL MASS SPECTROMETRY, 1981, 8 (05) :211-218
[2]   TRACER-TO-TRACEE RATIO FOR ANALYSIS OF STABLE ISOTOPE TRACER DATA - LINK WITH RADIOACTIVE KINETIC FORMALISM [J].
COBELLI, C ;
TOFFOLO, G ;
FOSTER, DM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (06) :E968-E975
[3]   ISOTOPE EFFECTS IN FRAGMENTATION [J].
DERRICK, PJ .
MASS SPECTROMETRY REVIEWS, 1983, 2 (02) :285-298
[4]   HIGH-PRECISION ISOTOPIC RATIO ANALYSIS OF VOLATILE METAL-CHELATES [J].
HACHEY, DL ;
BLAIS, JC ;
KLEIN, PD .
ANALYTICAL CHEMISTRY, 1980, 52 (07) :1131-1135
[5]   THE NONLINEARITY OF UPPER LIMITING PRESSURE FOR QUADRUPOLE MASS SPECTROMETERS [J].
HU, BS ;
QIU, JW .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1987, 5 (04) :2657-2660
[6]  
Latour MA, 1997, J LIPID RES, V38, P592
[7]   MEASUREMENT OF BIASES IN THE ELECTRON MULTIPLIER ION DETECTION SYSTEM OF A FINNIGAN-MAT MODEL 261 MASS-SPECTROMETER [J].
LOVERIDGE, WD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 74 (2-3) :197-206
[8]   SELECTED ION MONITORING MASS-SPECTROMETRY - PARAMETERS AFFECTING QUANTITATIVE-DETERMINATION [J].
LOW, IA ;
LIU, RH ;
BARKER, SA ;
FISH, F ;
SETTINE, RL ;
PIOTROWSKI, EG ;
DAMERT, WC ;
LIU, JY .
BIOMEDICAL MASS SPECTROMETRY, 1985, 12 (11) :633-637
[9]   GLYCEROL METABOLISM IN HUMANS - VALIDATION OF H-2-LABELED AND C-13-LABELED TRACERS [J].
MATTHEWS, DE ;
PESOLA, GR ;
KVETAN, V .
ACTA DIABETOLOGICA, 1991, 28 (02) :179-184
[10]   SYSTEMATIC-ERRORS IN GAS CHROMATOGRAPHY MASS SPECTROMETRY ISOTOPE RATIO MEASUREMENTS [J].
MATTHEWS, DE ;
HAYES, JM .
ANALYTICAL CHEMISTRY, 1976, 48 (09) :1375-1382