Improved vascular opacification in cerebral computed tomography angiography with 80 kVp

被引:88
作者
Bahner, ML
Bengel, A
Brix, G
Zuna, I
Kauczor, HU
Delorme, S
机构
[1] Deutsch Krebsforschungszentrum, Dept Radiol, D-69120 Heidelberg, Germany
[2] Fed Off Radiat Protect BfS, Div Med Radiat Hyg & Dosimetry, Neuherberg, Germany
关键词
spiral computed tomography; cerebral angiography; X-rays; contrast media;
D O I
10.1097/01.rli.0000155281.32319.52
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We sought to intraindividually compare computed tomography angiographies (CTAs) acquired at 80 kVp and 120 kVp with respect to vessel contrast, noise level, and radiation dose. Material and Methods: CTA was performed on a single-slice CT scanner using tube voltages of 80 kVp and 120 kVp in 29 patients with arteriovenous malformations. Mean Hounsfield Units (HU) were evaluated for different vessels and brain parenchyma. To determine contrast-to-noise ratios (CNRs), noise levels were estimated from phantom measurements. Results: The calculated effective dose to male/female patients was 0.4/0.5 mSv for 80 kVp and 0.7/0.8 mSv for 120 kVp. CT density in blood vessels was between 297 and 458 HU for 80 kVp and 152 and 229 HU for 120 kVp (P < 0.0001). Despite an increased noise level in the low-voltage images, the CNR was 26-59% higher at 80 kVp than at 120 kVp (P < 0.05). Conclusion: The use of a reduced tube potential leads to improved CNR in CTA of the cerebral vasculature and a markedly reduced radiation exposure to patients.
引用
收藏
页码:229 / 234
页数:6
相关论文
共 20 条
[1]   Optimal contrast application for cardiac 4-detector-row computed tomography [J].
Becker, CR ;
Hong, C ;
Knez, A ;
Leber, A ;
Bruening, R ;
Schoepf, UJ ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2003, 38 (11) :690-694
[2]   Contrast optimization and scan timing for single and multidetector-row computed tomography [J].
Brink, JA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 :S3-S8
[3]   Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study [J].
Brix, G ;
Lechel, U ;
Veit, R ;
Truckenbrodt, R ;
Stamm, G ;
Coppenrath, EM ;
Griebel, J ;
Nagel, HD .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1275-1284
[4]  
Diederichs CG, 1996, AM J NEURORADIOL, V17, P1758
[5]   Multi-detector row CT angiography of the brain at various kilovoltage settings [J].
Ertl-Wagner, BB ;
Hoffmann, RT ;
Bruning, R ;
Herrmann, K ;
Snyder, B ;
Blume, JD ;
Reiser, MF .
RADIOLOGY, 2004, 231 (02) :528-535
[6]   Use of high-concentration contrast media in multi pie-detector-row CT: principles and rationale [J].
Fleischmann, D .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M14-M20
[7]   High-concentration contrast media in MDCT angiography: principles and rationale [J].
Fleischmann, D .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 3) :N39-N43
[8]   Use of high concentration contrast media: principles and rationale - vascular district [J].
Fleischmann, D .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 :S88-S93
[9]   Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete Fourier transform [J].
Fleischmann, D ;
Hittmair, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :474-484
[10]   Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371