Feasibility and diagnostic accuracy of a gated SPECT early-imaging protocol: A multicenter study of the Myoview Imaging Optimization group

被引:43
作者
Giorgetti, Assuero [1 ]
Rossi, Massimiliano [1 ]
Stanislao, Mario [1 ]
Valle, Guido [1 ]
Bertolaccini, Pietro [1 ]
Maneschi, Alberto [1 ]
Giubbini, Raffaele [1 ]
De Rimini, Maria Luisa [1 ]
Mazzanti, Marco [1 ]
Cappagli, Mario [1 ]
Milan, Elisa [1 ]
Volterrani, Duccio [1 ]
Marzullo, Paolo [1 ]
机构
[1] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
关键词
tetrofosmin; gated SPECT; myocardial imaging; early imaging; delayed imaging; coronary artery disease;
D O I
10.2967/jnumed.106.039107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The aim of this study was to investigate whether early (time 1, or T1) myocardial tetrofosmin imaging is feasible and as accurate in detecting coronary artery disease as is standard delayed (time 2, or T2) imaging. Methods: One hundred twenty patients (100 men and 20 women; mean age +/- SD, 61 +/- 10 y) with anginal symptoms underwent tetrofosmin gated SPECT. Stress/rest T1 imaging was performed at 15 min and T2 at 45 min after injection. Image quality was visually evaluated using a 4-point scale (from 0 = poor to 3 = optimal). Myocardial perfusion analysis was performed on a 20-segment model using quantitative perfusion SPECT software, and reversible ischemia was scored as a summed difference score (SDS). Coronary angiography was performed within 1 mo on all patients, and stenosis of more than 50% of the diameter was considered significant. Results: Overall, quality was scored as optimal or good for 94% of T1 images and 95% of T2 images (P not statistically significant). Heart, lung, liver, and subdiaphragmatic counts did not differ for stress and rest T1 and T2 imaging. A good linear relationship was seen between T1 and T2 SIDS (r = 0.69; P < 0.0001), and Bland-Altman analysis showed good agreement between the 2 conditions. In terms of global diagnostic accuracy, areas under the receiver-operating-characteristic curve were comparable between T1 and T2 (0.80 vs. 0.81, P = not statistically significant). Discrepancies between T1 and T2 SIDS were observed in 44% of patients (T1 - T2 SDS > 2). Linear regression analysis showed a good correlation between T1 and T2 SDS (r = 0.67; P < 0.0001), whereas the Bland-Altman method showed a shift in the mean value of the difference of +2.67 +/- 2.73. In patients with a T1 - T2 SDS of more than 2, areas under the receiver-operating-characteristic curves were significantly higher for T1 than for T2 images (0.79 vs. 0.70, P < 0.001). Conclusion: T1 imaging is feasible and as accurate as T2 imaging in identifying coronary artery disease. However, in a discrete subset of patients, early acquisition strengthens the clinical message of defect reversibility by permitting earlier, more accurate identification of more severe myocardial ischemia.
引用
收藏
页码:1670 / 1675
页数:6
相关论文
共 19 条
[1]
Prolonged impairment of regional contractile function after resolution of exercise-induced angina - Evidence of myocardial stunning in patients with coronary artery disease [J].
Ambrosio, G ;
Betocchi, S ;
Pace, L ;
Losi, MA ;
PerroneFilardi, P ;
Soricelli, A ;
Piscione, F ;
Taube, J ;
Squame, F ;
Salvatore, M ;
Weiss, JL ;
Chiariello, M .
CIRCULATION, 1996, 94 (10) :2455-2464
[2]
Attenuation correction single-photon emission computed tomography myocardial perfusion imaging [J].
Bateman, TM ;
Cullom, SJ .
SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) :37-51
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Reversible regional wall motion abnormalities on exercise technetium-99m-gated cardiac single photon emission computed tomography predict high-grade angiographic stenoses [J].
Emmett, L ;
Iwanochko, RM ;
Freeman, MR ;
Barolet, A ;
Lee, DS ;
Husain, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) :991-998
[5]
Ferrara M, 1999, Sleep Res Online, V2, P15
[6]
Fleiss J. L., 1981, Statistical Methods for Rates and Proportions, V2nd
[7]
GERMANO G, 1994, J NUCL MED, V35, P356
[8]
GERMANO G, 1999, CLIN GATED CARDIAC S
[9]
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology [J].
Hesse, B ;
Tägil, K ;
Cuocolo, A ;
Anagnostopoulos, C ;
Bardiés, M ;
Bax, J ;
Bengel, F ;
Sokole, EB ;
Davies, G ;
Dondi, M ;
Edenbrandt, L ;
Franken, P ;
Kjaer, A ;
Knuuti, J ;
Lassmann, M ;
Ljungberg, M ;
Marcassa, C ;
Marie, PY ;
McKiddie, F ;
O'Connor, M ;
Prvulovich, E ;
Underwood, R ;
van Eck-Smit, B .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (07) :855-897
[10]
HIGLEY B, 1993, J NUCL MED, V34, P30