Attenuation correction single-photon emission computed tomography myocardial perfusion imaging

被引:52
作者
Bateman, TM
Cullom, SJ
机构
[1] Mid Amer Heart Inst, Kansas City, MO USA
[2] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
关键词
D O I
10.1053/j.semnuclmed.2004.09.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Clinicians now rely heavily on the results of single-photon emission computed tomography (SPECT) myocardial perfusion imaging for diagnosing coronary disease and for planning therapy. However, the technique is imperfect for these purposes, mainly because of technical limitations, the most prominent of which is the effect of soft-tissue attenuation on apparent tracer distribution. Providers have attempted to compensate for this by a number of indirect approaches. Recently, validated hardware and software solutions for directly correcting image data for soft-tissue attenuation have become widely available commercially. Optimal application requires an understanding of the technical details that differ somewhat from system to system, the quality control prerequisites, knowledge of the importance of the transmission map quality, and how dedicated SPECT and SPECT-computed tomography systems present different challenges. In addition, the clinical literature is expanding rapidly, including studies on diagnostic accuracy, image appearances, quantitative analysis, appropriate patients for attenuation correction, clinical utility, incremental value in relation to ECG-gating, and risk stratification. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:37 / 51
页数:15
相关论文
共 88 条
[1]   Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimeters [J].
Almeida, P ;
Bendriem, B ;
de Dreuille, O ;
Peltier, A ;
Perrot, C ;
Brulon, V .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (10) :1435-1441
[2]  
Almeida P, 1998, EUR J NUCL MED, V25, P1686
[3]   Clinical implication of down-scatter in attenuation-corrected myocardial SPECT [J].
Almquist, H ;
Arheden, H ;
Arvidsson, AH ;
Pahlm, O ;
Palmer, J .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) :406-411
[4]   ATTENUATION CORRECTION IN CARDIAC POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
BACHARACH, SL ;
BUVAT, I .
JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (03) :246-255
[5]   Transmission scanning in emission tomography [J].
Bailey, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (07) :774-787
[6]  
Bateman TM, 2003, CIRCULATION, V108, P455
[7]  
Beekman FJ, 1998, J NUCL MED, V39, P1996
[8]  
Bellemann M E, 2002, Biomed Tech (Berl), V47 Suppl 1 Pt 1, P474, DOI 10.1515/bmte.2002.47.s1a.474
[9]   Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images [J].
Bocher, M ;
Balan, A ;
Krausz, Y ;
Shrem, Y ;
Lonn, A ;
Wilk, M ;
Chisin, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (06) :619-627
[10]   Positron emission tomography/computed tomography-imaging protocols, artifacts, and pitfalls [J].
Bockisch, A ;
Beyer, T ;
Antoch, G ;
Freudenberg, LS ;
Kühl, H ;
Debatin, JF ;
Müller, SP .
MOLECULAR IMAGING AND BIOLOGY, 2004, 6 (04) :188-199