vibration;
modal analysis;
finite element model;
femur;
CT number;
D O I:
10.1016/S0021-9290(98)00018-9
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 [生物物理学];
摘要:
Frequency analysis of long bones has been investigated as a tool to assess bone quality or integrity. The objective of the present paper was to develop a three-dimensional finite element model of a fresh human femur with geometrical and mechanical properties derived from quantitative computer tomography images. This model was then exercised and the results were compared to those obtained from a vibration analysis technique. The percent relative error between the numerically and experimentally derived results was found about 4%. Finally, the influence of mechanical properties on the resonant spectre was studied. The results exhibit the limitations of the vibrational technique to detect slight material changes. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.