Separation of simulants of biological warfare agents from blood by a miniaturized dielectrophoresis device

被引:39
作者
Huang, Y
Yang, JM
Hopkins, PJ
Kassegne, S
Tirado, M
Forster, AH
Reese, H
机构
[1] Nanogen Inc, San Diego, CA 92121 USA
[2] Genoptix, San Diego, CA 92121 USA
[3] Univ Calif Irvine, Henri Samueli Sch Engn, Dept Mech & Aerosp Engn, Irvine, CA 92697 USA
关键词
separation; dielectrophoresis (DEP); biological warfare agents (BWA); miniaturization;
D O I
10.1023/A:1025760209483
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Separation of simulants of biological warfare agents from blood using dielectrophoresis (DEP) was demonstrated in a miniaturized DEP device. The device was fabricated by laminating five different layers (all 40 mm x 40 mm) including a polycarbonate substrate, a pressure sensitive acrylic adhesive (PSA) layer, a patterned polyimide layer with a flip-chip bonded dielectrophoresis chip (DEP chip), a PSA layer with microfluidic channel, and a glass cover plate. The DEP chip consisted of repetitive interdigitated electrodes with characteristic dimension of 50 pm. This device was employed to separate different simulants of biological warfare agents (BWA), namely Bacillus cereus (B. cereus), Escherichia coli (E. coli) and Listeria monocytogenes (L. monocytogenes), from blood, individually or simultaneously. PCR amplification, which was inhibited by blood components in pre-separation samples, successfully revealed bands in post-separation samples containing single or multiple BWA. Up to 97% efficiency of separation was achieved as demonstrated by culturing post-separation E. coli cells. The DEP device described here can potentially be used to reduce sample complexity for detection of infectious disease pathogens and biological warfare agents.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 36 条
[1]  
ADDERSON RC, 2000, NUCLEIC ACIDS RES, V28, pE60
[2]   SEPARATION OF HUMAN BREAST-CANCER CELLS FROM BLOOD BY DIFFERENTIAL DIELECTRIC AFFINITY [J].
BECKER, FF ;
WANG, XB ;
HUANG, Y ;
PETHIG, R ;
VYKOUKAL, J ;
GASCOYNE, PRC .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (03) :860-864
[3]   THE REMOVAL OF HUMAN LEUKEMIA-CELLS FROM BLOOD USING INTERDIGITATED MICROELECTRODES [J].
BECKER, FF ;
WANG, XB ;
HUANG, Y ;
PETHIG, R ;
VYKOUKAL, J ;
GASCOYNE, PRC .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1994, 27 (12) :2659-2662
[4]  
Belgrader P, 2001, ANAL CHEM, V73, P286, DOI 10.1021/ac000905v
[5]  
Brody J. P., 1995, 8th International Conference on Solid-State Sensors and Actuators and Eurosensors IX. Digest of Technical Papers (IEEE Cat. No.95TH8173), P779
[6]   Preparation and hybridization analysis of DNA/RNA from E-coli on microfabricated bioelectronic chips [J].
Cheng, J ;
Sheldon, EL ;
Wu, L ;
Uribe, A ;
Gerrue, LO ;
Carrino, J ;
Heller, MJ ;
O'Connell, JP .
NATURE BIOTECHNOLOGY, 1998, 16 (06) :541-546
[7]   Isolation of cultured cervical carcinoma cells mixed with peripheral blood cells on a bioelectronic chip [J].
Cheng, J ;
Sheldon, EL ;
Wu, L ;
Heller, MJ ;
O'Connell, JP .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2321-2326
[8]  
CRAIGHEAD H, 2000, SOL STAT SENS ACT WO, P26
[9]   A laminated, flex structure for electronic transport and hybridization of DNA [J].
Forster, AH ;
Krihak, M ;
Swanson, PD ;
Young, TC ;
Ackley, DE .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :187-194
[10]  
FUHR G, 1990, PLANT CELL PHYSIOL, V31, P975