The electronic nose as a rapid sensor for volatile compounds in treated domestic wastewater

被引:62
作者
Dewettinck, T [1 ]
Van Hege, K [1 ]
Verstraete, W [1 ]
机构
[1] State Univ Ghent, Lab Microbial Ecol & Ecol, LabMET, B-9000 Ghent, Belgium
关键词
electronic nose; domestic wastewater; water reuse; quality control; rapid sensor; volatile (organic) compounds;
D O I
10.1016/S0043-1354(00)00530-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An electronic nose consisting of 12 metal oxide sensors was used to monitor volatile compounds in effluent of a domestic wastewater treatment plant. Effluent and reference (deionized water) samples were heated to 60 and 90 degreesC to promote the volatilization and to increase the sensitivity. An effluent measuring campaign of 12 weeks was conducted and the repeatability and reproducibility of the procedure and the apparatus were determined. Processing the obtained fingerprints with principal component analysis (PCA) allowed interpretation and differentiation of the samples in terms of origin and quality, relative to the reference. To minimize the Variance due to sensitivity fluctuations of the apparatus and to detect effluents with deviating qualities, two new concepts were defined, i.e. the relative sensorial odour perception tin short: rSOP) and the relative fingerprint. Correlations between the relative overall electronic nose output, expressed as rSOP, and selected routine parameters were weak except for the parameter "volatile suspended solids" (VSS), indicating adsorption of volatile organic compounds (VOCs) onto the organic particles. The results clearly demonstrate the possibility to use the electronic nose as a rapid alarm generator towards volatile compounds, e.g. in specific advanced treatment processes to produce reclaimed water from effluent of the domestic wastewater treatment plant under scrutiny. (C) 2001 Elsevier Science Ltd. All rights reserved
引用
收藏
页码:2475 / 2483
页数:9
相关论文
共 39 条
  • [21] Howard P.H., 1991, HDB ENV FATE EXPOSUR
  • [22] JANSSENS I, 1996, P MEX 96 WORKSH BIOT
  • [23] Kaipainen A, 1997, INT SUGAR J, V99, P403
  • [24] Kress-Rogers E., 1997, HDB BIOSENSORS ELECT
  • [25] Measurements of some volatile compounds by means of the electronic nose
    Maricou, H
    Pereira, D
    Verschuere, L
    Philips, S
    Verstraete, W
    [J]. WATER AIR AND SOIL POLLUTION, 1998, 107 (1-4) : 423 - 442
  • [26] Use of an electronic nose to measure odour concentration following application of cattle slurry to grassland
    Misselbrook, TH
    Hobbs, PJ
    Persaud, KC
    [J]. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1997, 66 (03): : 213 - 220
  • [27] Odendaal P. E., 1998, WASTEWATER RECLAMATI, P1163
  • [28] Persaud K. C., 1992, SENSORS SENSORY SYST, P237
  • [29] Schwarzenbach R.P., 1993, J CHEM EDUC, DOI DOI 10.1021/ED070PA251.1
  • [30] Sittig M., 1980, PRIORITY TOXIC POLLU