Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study

被引:57
作者
Hussain, SM
De Becker, J
Hop, WCJ
Dwarkasing, S
Wielopolski, PA
机构
[1] Erasmus MC, Dept Radiol, Sect Abdominal Imaging, NL-3015 GD Rotterdam, Netherlands
[2] Philips Med Syst, Best, Netherlands
[3] Erasmus MC, Dept Epidemiol & Biostat, NL-3015 GD Rotterdam, Netherlands
关键词
liver; MR; echo-planar imaging; turbo spinecho; image optimization; image quality; T2-weighted images; black blood; diffusion-weighted imaging;
D O I
10.1002/jmri.20269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo USE) sequence. Materials and Methods: Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the. SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxons signed rank test for comparison of the SSBB-EPI and TSE sequences, with P 0.05 considered the limit for significance. Results: The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1- 4)) and TSE (3.6 (range: 3- 4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P >.05). Conclusion: Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence.
引用
收藏
页码:219 / 229
页数:11
相关论文
共 29 条
  • [11] Matsuo M, 2000, J MAGN RESON IMAGING, V12, P444, DOI 10.1002/1522-2586(200009)12:3<444::AID-JMRI10>3.3.CO
  • [12] 2-R
  • [13] Morrin M M, 2001, Magn Reson Imaging Clin N Am, V9, P675
  • [14] NAGAYAMA M, 2002, P 10 ANN M ISMRM HON
  • [15] Focal liver masses: Characterization with diffusion-weighted echo-planar MR imaging
    Namimoto, T
    Yamashita, Y
    Sumi, S
    Tang, Y
    Takahashi, M
    [J]. RADIOLOGY, 1997, 204 (03) : 739 - 744
  • [16] Breath-hold T2-weighted MRI of hepatic tumors: Value of echo planar imaging with diffusion-sensitizing gradient
    Okada, Y
    Ohtomo, K
    Kiryu, S
    Sasaki, Y
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (03) : 364 - 371
  • [17] ABDOMINAL MR-IMAGING - EVALUATION OF A FAST SPIN-ECHO SEQUENCE
    OUTWATER, EK
    MITCHELL, DG
    VINITSKI, S
    [J]. RADIOLOGY, 1994, 190 (02) : 425 - 429
  • [18] Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
  • [19] 2-S
  • [20] INITIAL FEASIBILITY STUDIES USING SINGLE-SHOT EPI FOR THE DETECTION OF FOCAL LIVER-LESIONS
    REIMER, P
    LADEBECK, R
    RUMMENY, EJ
    REPP, H
    SCHMITT, F
    BONGARTZ, G
    SCHUIERER, G
    LANGE, T
    PETERS, PE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (06) : 733 - 737