Voltammetric detection of copper(II) at a carbon paste electrode containing an organically modified silica

被引:125
作者
Etienne, M [1 ]
Bessiere, J [1 ]
Walcarius, A [1 ]
机构
[1] Univ Nancy 1, CNRS, UMR 7564, Lab Chim Phys Environm, F-54600 Villers Les Nancy, France
关键词
copper(II); aminopropyl-grafted silica gel; carbon paste; preconcentration; voltammetric detection;
D O I
10.1016/S0925-4005(01)00614-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode modified with aminopropyl-grafted silica gel (APS) was evaluated as an electrochemical sensor for copper species in aqueous medium. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte solution for the voltammetric quantification. During the preconcentration step, copper(II) was accumulated on the APS surface by complexation with the amine groups. In the detection step, copper(II) was desorbed in acidic medium, then cathodically electrolyzed at -0.5 V for 60 s, and detected by anodic stripping square wave voltammetry. The influence of various experimental parameters on the sensor response was investigated (i.e. pH of the detection and accumulation media, electrolysis time, carbon paste composition, silica gel porosity, accumulation time). Reproducible results were obtained, giving after optimization a linear calibration in the 5 x 10(-8)-2 x 10(-7) M concentration range, with a detection limit of 3 x 10(-9) M. This new sensor was applied to copper analysis in laboratory tap water. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 30 条
  • [1] Application of a chelite P modified carbon paste electrode to copper analysis and speciation
    Agraz, R
    deMiguel, J
    Sevilla, MT
    Hernandez, L
    [J]. ELECTROANALYSIS, 1996, 8 (06) : 565 - 570
  • [2] CHEMICALLY MODIFIED ELECTRODE FOR THE SIMULTANEOUS DETERMINATION OF TRACE-METALS AND SPECIATION ANALYSIS
    AGRAZ, R
    SEVILLA, MT
    HERNANDEZ, L
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 205 - 212
  • [3] VOLTAMMETRIC DETERMINATION OF TRACE-METALS AND ORGANICS AFTER ACCUMULATION AT MODIFIED ELECTRODES
    ARRIGAN, DWM
    [J]. ANALYST, 1994, 119 (09) : 1953 - 1966
  • [4] Copper
    Barceloux, DG
    [J]. JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1999, 37 (02): : 217 - 230
  • [5] Voltammetric response of a copper(II) complex incorporated in silica-modified carbon-paste electrode
    Borgo, CA
    Ferrari, RT
    Colpini, LMS
    Costa, CMM
    Baesso, ML
    Bento, AC
    [J]. ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 103 - 109
  • [6] Analytical applications of organically modified silicates
    Collinson, MM
    [J]. MIKROCHIMICA ACTA, 1998, 129 (3-4) : 149 - 165
  • [7] STRIPPING ELECTROANALYTICAL TECHNIQUES IN ENVIRONMENTAL-ANALYSIS
    ESTEBAN, M
    CASASSAS, E
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (03) : 110 - 117
  • [8] DETERMINATION OF COPPER(II) WITH A CARBON PASTE ELECTRODE MODIFIED WITH AN ION-EXCHANGE RESIN
    HERNANDEZ, L
    HERNANDEZ, P
    BLANCO, MH
    SANCHEZ, M
    [J]. ANALYST, 1988, 113 (01) : 41 - 43
  • [9] SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993
    KALCHER, K
    KAUFFMANN, JM
    WANG, J
    SVANCARA, I
    VYTRAS, K
    NEUHOLD, C
    YANG, Z
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 5 - 22
  • [10] KLONKOWSKI AM, 1991, J NON-CRYST SOLIDS, V129, P101