Monitoring local spatial distribution of Mg2+, pH and ionic currents

被引:114
作者
Lamaka, S. V. [1 ]
Karavai, O. V. [1 ]
Bastos, A. C. [1 ]
Zheludkevich, M. L. [1 ]
Ferreira, M. G. S. [1 ,2 ]
机构
[1] Univ Aveiro, CICECO, Dept Ceram & Glass Engn, P-3810193 Aveiro, Portugal
[2] Univ Tecn Lisboa, Inst Super Tecn, ICEMS, P-1049001 Lisbon, Portugal
关键词
SIET; ion-selective electrode; magnesium; alloy; SVET; corrosion;
D O I
10.1016/j.elecom.2007.12.003
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Micro ion-selective electrode techniques can analyze concentration of particular ions at the solid-liquid interface from the side of solution being an alternative, or a complement, to methods based on potential and current changes across the interface. We report the successful application of ion-selective micro-electrodes for mapping local activity of Mg2+ and H+ (by scanning ion-selective electrode technique, SIET) as well as local ionic current density measurements (by scanning vibrating electrode technique, SVET) over the surface of Mg-based alloy in aqueous chloride-containing solution. The local concentration of Mg2+ ions dissolved due to corrosion from artificial defects and pH changes together with cathodic and anodic currents are measured by combination of two selective and one vibrating microelectrodes. Combination of these techniques in one experiment gives a powerful tool for investigation mechanisms and kinetics of electrochemical corrosion processes in micro-confined zones. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:259 / 262
页数:4
相关论文
共 27 条
[1]  
[Anonymous], MATWEB MAT PROPERTY
[2]   Nanoelectrodes, nanoelectrode arrays and their applications [J].
Arrigan, DWM .
ANALYST, 2004, 129 (12) :1157-1165
[3]   The use of multiple electrochemical techniques to characterize Mg-rich primers for A1 alloys [J].
Bierwagen, Gordon ;
Battocchi, Dante ;
Simoes, Alda ;
Stamness, Anthony ;
Tallman, Dennis .
PROGRESS IN ORGANIC COATINGS, 2007, 59 (03) :172-178
[4]   Localized corrosion currents and pH profile over B4C, SiC, and Al2O3 reinforced 6092 aluminum composites -: I.: In 0.5 m Na2SO4 solution [J].
Ding, HB ;
Hihara, LH .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (04) :B161-B167
[5]   Constant-distance mode scanning potentiometry. 1. Visualization of calcium carbonate dissolution in aqueous solution [J].
Etienne, M ;
Schulte, A ;
Mann, S ;
Jordan, G ;
Dietzel, LD ;
Schuhmann, W .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3682-3688
[6]  
*EUROCORR, 2007, P WORKSH DEV SELF HE, P223
[7]   Simple procedure for the fabrication of silver/silver chloride potentiometric electrodes with micrometre and smaller dimensions: application to scanning electrochemical microscopy [J].
Gray, NJ ;
Unwin, PR .
ANALYST, 2000, 125 (05) :889-893
[8]   Multi-barrelled ion-sensitive microelectrodes and their application in micro-droplets and biological systems [J].
Günzel, D ;
Müller, A ;
Durry, S ;
Schlue, WR .
ELECTROCHIMICA ACTA, 1999, 44 (21-22) :3785-3793
[9]  
Isaacs H S, 1986, Prog Clin Biol Res, V210, P37
[10]   THE ELECTROCHEMICAL RESPONSE OF STEEL TO THE PRESENCE OF DISSOLVED CERIUM [J].
ISAACS, HS ;
DAVENPORT, AJ ;
SHIPLEY, A .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (02) :390-393