Evaluation of Novel Genetic Algorithm Generated Schemes for Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) Image Fusion

被引:10
作者
Baum, K. G. [1 ]
Schmidt, E. [3 ]
Rafferty, K. [1 ]
Krol, A. [2 ]
Helguera, Maria [1 ]
机构
[1] Rochester Inst Technol, Chester F Carlson Ctr Imaging Sci, Rochester, NY 14623 USA
[2] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
[3] Honeoye Falls Lima High Sch, Honeoye Falls, NY 14472 USA
关键词
Image fusion; Image display; Visual perception; Image perception; Image visualization; Clinical image viewing; Magnetic resonance imaging; Positron emission tomography; Breast; Genetic algorithm; Color mixing; Image enhancement; Artificial intelligence; Image analysis; Human visual system; BREAST-CANCER; FDG PET; WOMEN; DISPLAY; LESIONS; MAMMOGRAPHY; DISEASE; SCANNER; RISK; TOOL;
D O I
10.1007/s10278-011-9382-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use and benefits of a multimodality approach in the context of breast cancer imaging are discussed. Fusion techniques that allow multiple images to be viewed simultaneously are discussed. Many of these fusion techniques rely on the use of color tables. A genetic algorithm that generates color tables that have desired properties such as satisfying the order principle, the rows, and columns principle, have perceivable uniformity and have maximum contrast is introduced. The generated 2D color tables can be used for displaying fused datasets. The advantage the proposed method has over other techniques is the ability to consider a much larger set of possible color tables, ensuring that the best one is found. We asked radiologists to perform a set of tasks reading fused PET/MRI breast images obtained using eight different fusion techniques. This preliminary study clearly demonstrates the need and benefit of a joint display by estimating the inaccuracies incurred when using a side-by-side display. The study suggests that the color tables generated by the genetic algorithm are good choices for fusing MR and PET images. It is interesting to note that popular techniques such as the Fire/Gray and techniques based on the HSV color space, which are prevalent in the literature and clinical practice, appear to give poorer performance.
引用
收藏
页码:1031 / 1043
页数:13
相关论文
共 40 条
[1]   Intensity-modulated parametric mapping for simultaneous display of rapid dynamic and high-spatial-resolution breast MR imaging data [J].
Agoston, AT ;
Daniel, BL ;
Herfkens, RJ ;
Ikeda, DM ;
Birdwell, RL ;
Heiss, SG ;
Sawyer-Glover, AM .
RADIOGRAPHICS, 2001, 21 (01) :217-226
[2]  
[Anonymous], ImageJ
[3]   Classification of hypervascularized lesions in CE MR imaging of the breast [J].
Baum, F ;
Fischer, U ;
Vosshenrich, R ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1087-1092
[4]   Fusion Viewer: A New Tool for Fusion and Visualization of Multimodal Medical Data Sets [J].
Baum, Karl G. ;
Helguera, Maria ;
Krol, Andrzej .
JOURNAL OF DIGITAL IMAGING, 2008, 21 (Suppl 1) :S59-S68
[5]   A new application for displaying and fusing multimodal data sets [J].
Baum, Karl G. ;
Helguera, Maria ;
Krol, Andrzej .
MULTIMODAL BIOMEDICAL IMAGING II, 2007, 6431
[6]  
BAUM KG, 2008, THESIS ROCHESTER I T
[7]  
Baum KG, 2007, P IEEE INT C IM PROC, DOI [10.1109/ICIP.2006.312806, DOI 10.1109/ICIP.2006.312806]
[8]  
Beaulieu S, 2003, J NUCL MED, V44, P1044
[9]  
Bergquist SL, 1997, J GEN PSYCHOL, V97, P145
[10]  
Bombardieri E, 2001, Q J NUCL MED, V45, P245