Synchrotron hard x-ray microprobe:: Fluorescence imaging of single cells

被引:86
作者
Bohic, S
Simionovici, A
Snigirev, A
Ortega, R
Devès, G
Heymann, D
Schroer, CG
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] Univ Bordeaux 1, LCNAB, CNRS, UMR 5084, F-33175 Gradignan, France
[3] Lab Physiopatol Resorpt Osseuse, Nantes, France
[4] Rhein Westfal TH Aachen, Inst Phys 2, D-52056 Aachen, Germany
关键词
D O I
10.1063/1.1366362
中图分类号
O59 [应用物理学];
学科分类号
摘要
Imaging of trace elements in single cells was achieved by synchrotron-induced x-ray fluorescence (SXRF) in the hard x-ray range. Monochromatic and "pink" excitations at 14 keV were used with compound refractive lenses resulting in a 1x10 mum(2) beam size. The experiment shows that SXRF is well suited for microanalysis of freeze-dried cells, and demonstrated high accuracy in quantitative imaging of trace element in cells treated with pharmacological doses of an iodine-labeled anticancer drug. (C) 2001 American Institute of Physics.
引用
收藏
页码:3544 / 3546
页数:3
相关论文
共 23 条
[1]   Microscopic X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources - Plenary lecture [J].
Adams, F ;
Janssens, K ;
Snigirev, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) :319-331
[2]   X-ray microprobes [J].
Chevallier, P ;
Dhez, P ;
Erko, A ;
Firsov, A ;
Legrand, F ;
Populus, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 113 (1-4) :122-127
[3]  
CHUBAR O, 1998, P 6 EUR PART ACC C E, P1177
[4]   ANOMALOUS DISPERSION CALCULATIONS NEAR TO AND ON THE LONG-WAVELENGTH SIDE OF AN ABSORPTION-EDGE [J].
CROMER, DT ;
LIBERMAN, DA .
ACTA CRYSTALLOGRAPHICA SECTION A, 1981, 37 (MAR) :267-268
[5]   RELATIVISTIC CALCULATION OF ANOMALOUS SCATTERING FACTORS FOR X-RAYS [J].
CROMER, DT ;
LIBERMAN, D .
JOURNAL OF CHEMICAL PHYSICS, 1970, 53 (05) :1891-&
[6]   XOP: A multiplatform graphical user interface for synchrotron radiation spectral and optics calculations. [J].
del Rio, MS ;
Dejus, RJ .
MATERIALS, MANUFACTURING, AND MEASUREMENT FOR SYNCHROTRON RADIATION MIRRORS, 1997, 3152 :148-157
[7]  
Janssens K. H. A., 2000, MICROSCOPIC XRAY FLU
[8]   ATOMIC RADIATIVE AND RADIATIONLESS YIELDS FOR K-SHELLS AND L-SHELLS [J].
KRAUSE, MO .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1979, 8 (02) :307-327
[9]   HARD X-RAY PHASE ZONE PLATE FABRICATED BY LITHOGRAPHIC TECHNIQUES [J].
LAI, B ;
YUN, WB ;
LEGNINI, D ;
XIAO, Y ;
CHRZAS, J ;
VICCARO, PJ ;
WHITE, V ;
BAJIKAR, S ;
DENTON, D ;
CERRINA, F ;
DIFABRIZIO, E ;
GENTILI, M ;
GRELLA, L ;
BACIOCCHI, M .
APPLIED PHYSICS LETTERS, 1992, 61 (16) :1877-1879
[10]   Imaging by parabolic refractive lenses in the hard X-ray range [J].
Lengeler, B ;
Schroer, C ;
Tümmler, J ;
Benner, B ;
Richwin, M ;
Snigirev, A ;
Snigireva, I ;
Drakopoulos, M .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :1153-1167