Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: A truly hybrid x-ray/MR imaging system

被引:21
作者
Fahrig, R [1 ]
Wen, Z
Ganguly, A
DeCrescenzo, G
Rowlands, JA
Stevens, GM
Saunders, RF
Pelc, NJ
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
[3] Univ Toronto, Sunnybrook & Womens Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[4] GE Healthcare, Schenectady, WI USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
interventional MR; hybrid system; static anode x-ray tube; flat-panel x-ray detector;
D O I
10.1118/1.1915016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Minimally invasive procedures are increasing in variety and frequency, facilitated by advances in imaging technology. Our hybrid imaging system (GE Apollo (TM) flat panel, custom Brand x-ray static anode x-ray tube, GE Lunar high-frequency power supply and 0.5 T Signa SP (TM)) provides both x-ray and MR imaging capability to guide complex procedures without requiring motion of the patient between two distant gantries. The performance of the x-ray tube in this closely integrated system was evaluated by modeling and measuring both the response of the filament to an externally applied field and the behavior of the electron beam for field strengths and geometries of interest. The performance of the detector was assessed by measuring the slanted-edge modulation transfer function (MTF) and when placed at zero field and at 0.5 T. Measured resonant frequencies of filaments can be approximated using a modified vibrating beam model, and were at frequencies well below the 25 kHz frequency of our generator for our filament geometry. The amplitude of vibration was not sufficient to cause shorting of the filament during operation within the magnetic field. A simple model of electrons in uniform electric and magnetic fields can be used to estimate the deflection of the electron beam on the anode for the fields of interest between 0.2 and 0.5 T. The MTF measured at the detector and the DQE showed no significant difference inside and outside of the magnetic field. With the proper modifications, an x-ray system can be fully integrated with a MR system, with minimal loss of image quality. Any x-ray tube can be assessed for compatibility when placed at a particular location within the field using the models. We have also concluded that a-Si electronics ate robust against magnetic fields. Detailed knowledge of the x-ray system installation is required to provide estimates of system operation. C 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1775 / 1784
页数:10
相关论文
共 25 条
[1]  
[Anonymous], 1950, MECH DEFORMABLE BODI
[2]   Measurement of the noise power spectrum in digital x-ray detectors [J].
Aufrichtig, R ;
Su, Y ;
Cheng, Y ;
Granfors, PR .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :362-372
[3]  
Chu RM, 2001, NEUROIMAG CLIN N AM, V11, P715
[4]   A METHOD FOR MODULATION TRANSFER-FUNCTION DETERMINATION FROM EDGE PROFILES WITH CORRECTION FOR FINITE-ELEMENT DIFFERENTIATION [J].
CUNNINGHAM, IA ;
FENSTER, A .
MEDICAL PHYSICS, 1987, 14 (04) :533-537
[5]   SIGNAL AND NOISE IN MODULATION TRANSFER-FUNCTION DETERMINATIONS USING THE SLIT, WIRE, AND EDGE TECHNIQUES [J].
CUNNINGHAM, IA ;
REID, BK .
MEDICAL PHYSICS, 1992, 19 (04) :1037-1044
[6]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[7]  
Fahrig R, 2002, RADIOLOGY, V225, P545
[8]   Truly hybrid interventional MR/x-ray system: Investigation of in vivo applications [J].
Fahrig, R ;
Butts, K ;
Wen, ZF ;
Saunders, R ;
Kee, ST ;
Sze, DY ;
Daniel, BL ;
Laerum, F ;
Pelc, NJ .
ACADEMIC RADIOLOGY, 2001, 8 (12) :1200-1207
[9]  
Fahrig R, 2001, J MAGN RESON IMAGING, V13, P294, DOI 10.1002/1522-2586(200102)13:2<294::AID-JMRI1042>3.0.CO
[10]  
2-X