Fast sequential injection determination of benzo[A]pyrene using variable angle fluorescence with on-line solid-phase extraction

被引:38
作者
Erustes, JA
Andrade-Eiroa, A
Cladera, A
Forteza, R
Cerdà, V
机构
[1] Univ Balearic Isl, Dept Chem, E-07071 Palma de Mallorca, Spain
[2] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
关键词
D O I
10.1039/b010129j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A methodology for the analysis of drinking water for one of the most potent carcinogenic agents known; benzo[a]pyrene (BaP), in the presence of other interfering PAHs is presented. The methodology described is based on the sequential injection analysis of the sample on to a microcolumn (containing 5 mg of C-18) where extraction and preconcentration of BaP takes place, followed by elution of BaP with 1 ml of 1,4-dioxane and subsequent detection by using variable angle fluorescence. The advantages of the method include the small amount of stationary phase employed together with the possibility of re-using the phase in order to carry out a large number of injections without the need for column re-packing. Also noteworthy is the small volume of 1,4-dioxane used to elute the BaP retained on the column and the small sample volumes required (9-10 ml) for achieving detection limits at the ng 1(-1) level. Thus, a methodology for BaP determination is obtained which complies with the requirements of the 98/83/EC Directive which fixes a maximum admissible concentration for this pollutant in waters for public consumption of 10 ng 1(-1). The variable angle spectra obtained are further processed by means of the multiple linear regression technique. The detection limit for BaP is 2.5 ng 1(-1), and the linear range is between 7.5 and 280 ng 1(-1).
引用
收藏
页码:451 / 456
页数:6
相关论文
共 30 条
  • [1] A robust multisyringe system for process flow analysis -: Part I.: On-line dilution and single point titration of protolytes
    Albertús, F
    Horstkotte, B
    Cladera, A
    Cerdá, V
    [J]. ANALYST, 1999, 124 (09) : 1373 - 1381
  • [2] Resolution of a multicomponent polycyclic aromatic hydrocarbon system in micellar media by linear variable angle fluorescence applying distinct chemometric techniques
    Amador-Hernández, J
    Cladera, A
    Estela, JM
    López-de-Alba, PL
    Cerdà, V
    [J]. ANALYST, 1998, 123 (11) : 2235 - 2241
  • [3] DETERMINATION OF PYRENE AND BENZO(A)PYRENE RESIDUES IN WATER BY DERIVATIVE SYNCHRONOUS SOLID-PHASE SPECTROFLUOROMETRY
    CAPITANVALLVEY, LF
    CASTANEDA, RA
    IRUELA, MD
    QUERO, JLV
    [J]. MIKROCHIMICA ACTA, 1993, 112 (1-4) : 55 - 62
  • [4] Resolution of benzo[a]pyrene in complex mixtures of other polycyclic aromatic hydrocarbons.: Comparison of two spectrofluorimetric methods applied to water samples
    Eiroa, AA
    Blanco, EV
    Mahía, PL
    Lorenzo, SM
    Rodríguez, DP
    [J]. ANALYST, 2000, 125 (07) : 1321 - 1326
  • [5] Determination of polycyclic aromatic hydrocarbons (PAHs) in a complex mixture by second-derivative constant-energy synchronous spectrofluorimetry
    Eiroa, AA
    Blanco, EV
    Mahía, PL
    Lorenzo, SM
    Rodríguez, DP
    Fernández, EF
    [J]. TALANTA, 2000, 51 (04) : 677 - 684
  • [6] Application of the effects of solvent and dissolved oxygen on the determination of benzo[a]pyrene by constant-wavelength synchronous spectrofluorimetry in smoke-flavouring
    Falcón, MSG
    Amigo, SG
    Yusty, MAL
    Lage, BL
    Lozano, JS
    [J]. TALANTA, 1999, 48 (02) : 377 - 384
  • [7] GASOLINE-ENGINE EXHAUST ANALYSIS USING CONSTANT ENERGY SYNCHRONOUS LUMINESCENCE SPECTROMETRY
    FILES, LA
    JONES, BT
    HANAMURA, S
    WINEFORDNER, JD
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (07) : 1440 - 1443
  • [8] Futoma D. J., 1981, POLYCYCLIC AROMATIC
  • [9] ORGANICS IN WATER - SOLID-PHASE EXTRACTION ON A SMALL-SCALE
    JUNK, GA
    RICHARD, JJ
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (05) : 451 - 454
  • [10] LIN Y, 1998, FENXI CESHI XUEBAO, V17, P66