Heat storage and anthropogenic heat flux in relation to the energy balance of a central European city centre

被引:171
作者
Offerle, B
Grimmond, CSB
Fortuniak, K
机构
[1] Indiana Univ, Dept Geog, Atmospher Sci Program, Bloomington, IN 47405 USA
[2] Univ Gothenburg, Gothenburg, Sweden
[3] Univ Lodz, PL-90131 Lodz, Poland
关键词
urban energy balance; storage heat flux; anthropogenic heat flux;
D O I
10.1002/joc.1198
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The role of net heat storage Delta Q(S) and anthropogenic heat Q(F) are considered in the surface energy balance for a downtown area in Lodz, Poland, for a 2 year period. Eddy covariance measurements provide estimates of the turbulent heat fluxes and radiometric measurements of the net all-wave radiation. A method to determine Delta Q(S) based on representative surface temperature sampling is employed and compared with results from two other models. Results show that Delta Q(S) is an important flux on the scale of hours to days and that it can be more than 10 W m(-2), on average, for periods of a week or more. By incorporating Delta Q(S) estimates over hourly intervals, Q(F) was then determined as the residual of the energy balance. Using the approach, Q(F) averaged 32 W m(-2) from October to March (60% of available energy), and -3 W m(-2) from June to August. The physically unrealistic negative values for the summer period may suggest underestimation of turbulent fluxes, but no causal factor was identified. Although energy balance closure was close to 100% throughout the year, there was weaker agreement in the winter. This is attributed to errors in estimates of Delta Q(S) and variation in Q(F). Results highlight the need for future investigations of the urban surface energy balance to incorporate more complete measurements and estimates of Delta Q(S). Copyright (c) 2005 Royal Meteorological Society.
引用
收藏
页码:1405 / 1419
页数:15
相关论文
共 48 条
[41]   Comparison of summer- and winter-time suburban energy fluxes in Christchurch, New Zealand [J].
Spronken-Smith, RA .
INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2002, 22 (08) :979-992
[42]   Spectral characteristics and correction of long-term eddy-covariance measurements over two mixed hardwood forests in non-flat terrain [J].
Su, HB ;
Schmid, HP ;
Grimmond, CSB ;
Vogel, CS ;
Oliphant, AJ .
BOUNDARY-LAYER METEOROLOGY, 2004, 110 (02) :213-253
[43]  
Taha H, 1999, J APPL METEOROL, V38, P466, DOI 10.1175/1520-0450(1999)038<0466:MAMMMT>2.0.CO
[44]  
2
[45]   Typical building arrangements for urban air pollution modelling [J].
Theurer, W .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (24-25) :4057-4066
[46]  
Vickers D, 1997, J ATMOS OCEAN TECH, V14, P512, DOI 10.1175/1520-0426(1997)014<0512:QCAFSP>2.0.CO
[47]  
2
[48]   Energy balance closure at FLUXNET sites [J].
Wilson, K ;
Goldstein, A ;
Falge, E ;
Aubinet, M ;
Baldocchi, D ;
Berbigier, P ;
Bernhofer, C ;
Ceulemans, R ;
Dolman, H ;
Field, C ;
Grelle, A ;
Ibrom, A ;
Law, BE ;
Kowalski, A ;
Meyers, T ;
Moncrieff, J ;
Monson, R ;
Oechel, W ;
Tenhunen, J ;
Valentini, R ;
Verma, S .
AGRICULTURAL AND FOREST METEOROLOGY, 2002, 113 (1-4) :223-243