Reproducibility and side differences of mechanical tests for determining the structural strength of the proximal femur

被引:84
作者
Eckstein, F
Wunderer, C
Boehm, H
Kuhn, V
Priemel, M
Link, TM
Lochmüller, EM
机构
[1] Paracelsus Med Private Univ, Inst Anat, A-5020 Salzburg, Austria
[2] Univ Munich, Inst Anat, Musculoskeletal Res Grp, Munich, Germany
[3] Univ Munich, Dept Gynecol 1, Munich, Germany
[4] Tech Univ, Dept Radiol, Munich, Germany
[5] Max Planck Gesell, Inst Extraterr Phys, Garching, Germany
[6] Univ Hamburg, Sch Med, Dept Trauma Surg, Hamburg, Germany
关键词
bone mechanics; bone strength; femur; mechanics; reproducibility;
D O I
10.1359/JBMR.0301247
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
In this experimental study, we evaluated the reproducibility error of mechanical strength tests of the proximal femur when simulating a fall on the trochanter. Based on side differences in femoral failure loads in 55 pairs of femora, we estimated the upper limit of the precision error to be 15% for the side impact test, whereas the intersubject variability was >40%. Introduction: Mechanical tests are commonly used as the gold standard for determining one of the main functions of bones, that is, to provide mechanical strength. However, it is unknown what magnitude of error is associated with these tests. Here we investigate the precision error and side difference of a side impact test of the proximal femur. Materials and Methods: BMC was measured using DXA in 54 pairs of femora from donors 79.0 +/- 10.6 years of age. Bones were tested to failure, simulating a fall on the greater trochanter. Results: Failure loads were 3951 +/- 1659N (CV% = 42%) on the right and 3900 +/- 1652N (CV% = 42%) on the left (no significant side difference). The average random difference of femoral BMC was 7 +/- 7% and that of femoral failure loads was 17 +/- 12%. The correlation between BMC and failure load was 79% (r(2)), but the association between side differences in failure load with those in BMC was only 4%. When confining the analysis to pairs with less than 5% differences in BMC (n = 31), side differences in failure loads were 15 +/- 13%. When correcting failure loads for side differences of BMC, the difference was 16 15% Conclusions: These results suggest that the upper limit of the precision error for femoral strength tests is similar to15% in a side impact configuration. Given the large intersubject Variability of failure loads, this test provides an efficient tool for determining the structural strength of the proximal femur in a fall.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 62 条
[1]
ALHO A, 1988, CLIN ORTHOP RELAT R, P292
[2]
Augat P, 1996, J BONE MINER RES, V11, P1356
[3]
PREDICTING FEMORAL-NECK STRENGTH FROM BONE-MINERAL DATA - A STRUCTURAL APPROACH [J].
BECK, TJ ;
RUFF, CB ;
WARDEN, KE ;
SCOTT, WW ;
RAO, GU .
INVESTIGATIVE RADIOLOGY, 1990, 25 (01) :6-18
[4]
Experimental testing of a DEXA-derived curved beam model of the proximal femur [J].
Beck, TJ ;
Mourtada, FA ;
Ruff, CB ;
Scott, WW ;
Kao, G .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (03) :394-398
[5]
Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia [J].
Bouxsein, ML ;
Coan, BS ;
Lee, SC .
BONE, 1999, 25 (01) :49-54
[6]
ULTRASOUND AND DENSITOMETRY OF THE CALCANEUS CORRELATE WITH THE FAILURE LOADS OF CADAVERIC FEMURS [J].
BOUXSEIN, ML ;
COURTNEY, AC ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (02) :99-103
[7]
Assessment of the strength of proximal femur in vitro: Relationship to femoral bone mineral density and femoral geometry [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
Brys, P ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 20 (03) :213-218
[8]
CHHIBBER SR, 1970, J ANAT, V106, P553
[9]
Femoral strength is better predicted by finite element models than QCT and DXA [J].
Cody, DD ;
Gross, GJ ;
Hou, FJ ;
Spencer, HJ ;
Goldstein, SA ;
Fyhrie, DP .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1013-1020
[10]
HIP-FRACTURES IN THE ELDERLY - A WORLDWIDE PROJECTION [J].
COOPER, C ;
CAMPION, G ;
MELTON, LJ .
OSTEOPOROSIS INTERNATIONAL, 1992, 2 (06) :285-289