High-Resolution Interleaved Water-Fat MR Imaging of Finger Joints With Chemical-Shift Elimination

被引:2
作者
Kwok, Wingchi E. [1 ,2 ]
You, Zhigang
Seo, Gwysuk
Lerner, Amy [3 ]
Totterman, Saara [4 ]
Ritchlin, Christopher [5 ]
Monu, Johnny
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
[2] Univ Rochester, Rochester Ctr Brain Imaging, Rochester, NY 14642 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14642 USA
[4] Qimaging, Rochester, NY USA
[5] Univ Rochester, Med Ctr, Allergy Immunol & Rheumatol Div, Rochester, NY 14642 USA
关键词
high-resolution MRI; water-fat imaging; chemical-shift artifacts; musculoskeletal MRI; finger joints; arthritis; RHEUMATOID-ARTHRITIS; PSORIATIC-ARTHRITIS; DIXON TECHNIQUE; EROSIONS; HAND; OSTEOARTHRITIS; DECOMPOSITION; TOMOGRAPHY; SEQUENCES;
D O I
10.1002/jmri.22427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To study the use of an interleaved water-fat (IWF) sequence with a custom-made radiofrequency (RF) coil for high-resolution imaging of arthritic finger joints. Materials and Methods: High-resolution finger magnetic resonance imaging (MRI) was performed using a custom-made dedicated RF receiver coil and an IWF sequence. A phantom, a cadaver finger specimen, and the fingers of two normal controls and six arthritic subjects were imaged with a resolution of 156 x 156 x 600 mu m. The appearance of anatomic structures on the IWF images were compared with images acquired with a regular sequence. The images were reviewed by two musculoskeletal radiologists for the depiction of anatomical structures and for the presence of abnormalities. Results: The high-resolution images revealed detailed structures of the finger joints not detectable using typical clinical resolution. The IWF sequence gave more realistic depiction of subchondral bone thickness, and avoided false bone erosions displayed in the regular sequence. It also allowed better visualization of ligaments and tendons. Conclusion: This pilot study shows the feasibility and the potential usefulness of high-resolution IWF imaging for finger joint evaluation. This technique may be useful for the diagnosis and treatment assessment of arthritis, and for the study of joint disease pathogenesis.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 21 条
[1]
Alasaarela E, 1998, BRIT J RHEUMATOL, V37, P1152
[2]
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[3]
Frontiers in musculoskeletal imaging [J].
Crues, John ;
Bydder, Graeme .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) :232-233
[4]
Advanced imaging in rheumatoid arthritis - Part 2: Erosions [J].
Farrant, J. M. ;
Grainger, A. J. ;
O'Connor, P. J. .
SKELETAL RADIOLOGY, 2007, 36 (05) :381-389
[5]
Advanced imaging in rheumatoid arthritis - Part 1: Synovitis [J].
Farrant, J. M. ;
O'Connor, P. J. ;
Grainger, A. J. .
SKELETAL RADIOLOGY, 2007, 36 (04) :269-279
[6]
HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE INTERPHALANGEAL JOINTS OF THE HAND [J].
FRY, ME ;
JACOBY, RK ;
HUTTON, CW ;
ELLIS, RE ;
PITTARD, S ;
VENNART, W .
SKELETAL RADIOLOGY, 1991, 20 (04) :273-277
[7]
3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[8]
Kwok WE, 2000, MAGNET RESON MED, V44, P322, DOI 10.1002/1522-2594(200008)44:2<322::AID-MRM21>3.0.CO
[9]
2-Q
[10]
High-Resolution Uniform MR Imaging of Finger Joints Using a Dedicated RF Coil at 3T [J].
Kwok, Wingchi E. ;
You, Zhigang ;
Monu, Johnny ;
Seo, Gwysuk ;
Ritchlin, Christopher .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) :240-247