High-Resolution Uniform MR Imaging of Finger Joints Using a Dedicated RF Coil at 3T

被引:11
作者
Kwok, Wingchi E. [1 ,2 ]
You, Zhigang
Monu, Johnny
Seo, Gwysuk
Ritchlin, Christopher [3 ]
机构
[1] Univ Rochester, Dept Imaging Sci, Med Ctr, Rochester, NY 14642 USA
[2] Univ Rochester, Rochester Ctr Brain Imaging, Rochester, NY 14642 USA
[3] Univ Rochester, Med Ctr, Allergy Immunol & Rheumatol Div, Rochester, NY 14642 USA
基金
美国国家卫生研究院;
关键词
high-resolution MRI; MR microscopy; RF receive coil; musculoskeletal MRI; finger joints; arthritis; RHEUMATOID-ARTHRITIS; PSORIATIC-ARTHRITIS; OSTEOARTHRITIS; DACTYLITIS; ENTHESIS;
D O I
10.1002/jmri.21984
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To develop a dedicated radiofrequency (RF) Coil for high-resolution magnetic resonance imaging (MRI) of finger joints at 3T to improve diagnostic evaluation of arthritic diseases. Materials and Methods: A dedicated cylindrical RF receive coil was developed for imaging finger joints at 3T. A planar coil, a saddle coil, and a 1.5T coil with similar design as the dedicated coil were also constructed to compare imaging performance with the dedicated coil. A phantom was used for quantitative evaluation. Three-dimensional images were obtained on four subjects and a cadaver finger specimen using isotropic resolution of 160 mu m in 9:32 minutes. The images were reviewed by two musculoskeletal radiologists. Results: The dedicated finger coil provided higher signal-to-noise and greater signal uniformity than the other coils. It supported high-resolution imaging that demonstrated anatomical details of the entire finger joint, and in the subject study revealed abnormalities not detectable by traditional clinical resolution. Conclusion: The dedicated ringer coil optimizes the potential advantages of 3T scanners compared to lower field magnets. Use of this coil should facilitate early diagnosis, improve assessment of treatment response, and provide better understanding of basic mechanisms that underlie arthritis.
引用
收藏
页码:240 / 247
页数:8
相关论文
共 22 条
[1]
Is MRI fulfilling its promise for molecular imaging of cartilage in arthritis? [J].
Burstein, D. ;
Gray, M. L. .
OSTEOARTHRITIS AND CARTILAGE, 2006, 14 (11) :1087-1090
[2]
Frontiers in musculoskeletal imaging [J].
Crues, John ;
Bydder, Graeme .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) :232-233
[3]
Enthesitis [J].
D'Agostino, Maria Antonietta ;
Olivieri, Ignazio .
BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2006, 20 (03) :473-486
[4]
Advanced imaging in rheumatoid arthritis - Part 2: Erosions [J].
Farrant, J. M. ;
Grainger, A. J. ;
O'Connor, P. J. .
SKELETAL RADIOLOGY, 2007, 36 (05) :381-389
[5]
Advanced imaging in rheumatoid arthritis - Part 1: Synovitis [J].
Farrant, J. M. ;
O'Connor, P. J. ;
Grainger, A. J. .
SKELETAL RADIOLOGY, 2007, 36 (04) :269-279
[6]
Modified birdcage coils for targeted imaging [J].
Gasson, J ;
Summers, IR ;
Fry, ME ;
Vennart, W .
MAGNETIC RESONANCE IMAGING, 1995, 13 (07) :1003-1012
[7]
Magnetic resonance imaging of rheumatoid arthritis in metacarpophalangeal joints [J].
Gasson, J ;
Gandy, SJ ;
Hutton, CW ;
Jacoby, RK ;
Summers, IR ;
Vennart, W .
SKELETAL RADIOLOGY, 2000, 29 (06) :324-334
[8]
Assessment of patients with psoriatic arthritis - A review of currently available measures [J].
Gladman, DD ;
Helliwell, P ;
Mease, PJ ;
Nash, P ;
Ritchlin, C ;
Taylor, W .
ARTHRITIS AND RHEUMATISM, 2004, 50 (01) :24-35
[9]
Helliwell PS, 2006, J RHEUMATOL, V33, P1439
[10]
KWOK WE, 2006, P 92 ANN M RAD SOC N, P282