Left Ventricular Support by Axial Flow Pump: The Echocardiographic Approach to Device Malfunction

被引:28
作者
Catena, Emanuele [1 ]
Milazzo, Filippo [1 ]
Montorsi, Emanuela [1 ]
Bruschi, Giuseppe
Cannata, Aldo
Russo, Claudio
Barosi, Alberto
Tarelli, Giuseppe
Tartara, Paolo
Paino, Roberto [1 ]
Vitali, Ettore
机构
[1] Osped Niguarda Ca Granda, Div Cardiothorac Anesthesia & Intens Care, Milan, Italy
关键词
D O I
10.1016/j.echo.2005.04.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Axial flow pumps have gained increased acceptance in recent years as a bridge to heart transplantation and, more recently, as destination therapy. As left ventricular (LV) assist device dysfunction will be increasingly prevalent, the aim of our work was to introduce an echocardiographic management protocol as a guide to recognize the causes of pump failure. In this article we describe the echocardiographic approach to 5 episodes of malfunction of an axial flow pump (DeBakey, MicroMed Technology Inc, Houston, Tex) in 4 patients: 4 episodes caused by thrombosis of LV assist device and one caused by abnormal increase of systemic vascular resistance. In our experience, echocardiography played a pivotal role in clinical management of LV assist device failure. It allowed us to: assess patency and position of inflow and outflow cannulae; research the source of thromboembolic material; assess adequate LV filling and unloading; and optimize right ventricular function, volume replacement therapy, and pharmacologic support.
引用
收藏
页码:1422.e7 / 1422.e13
页数:7
相关论文
共 17 条
[1]  
BARZILAI B, 1992, J THORAC CARDIOV SUR, V104, P1410
[2]   Device therapy for heart failure [J].
Boehmer, JP .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (6A) :53D-59D
[3]   Transesophageal echocardiographic evaluation of patients receiving mechanical assistance from ventricular assist devices [J].
DavilaRoman, VG ;
Barzilai, B .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (05) :505-511
[4]   Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation [J].
Goldstein, DJ .
CIRCULATION, 2003, 108 (10) :272-277
[5]   Bridge to transplantation with the DeBakey VAD® axial pump:: a single center report [J].
Grinda, JM ;
Latremouille, CH ;
Chevalier, P ;
D'Attelis, N ;
Boughenou, F ;
Guillemain, R ;
Deloche, A ;
Fabiani, JN .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (06) :965-970
[6]   Left ventricular assist device malfunction: A systematic approach to diagnosis [J].
Horton, SC ;
Khodaverdian, R ;
Powers, A ;
Revenaugh, J ;
Renlund, DG ;
Moore, SA ;
Rasmusson, B ;
Nelson, KE ;
Long, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (09) :1574-1583
[7]  
Leibowitz D W, 1994, J Am Soc Echocardiogr, V7, P624
[8]  
Livingston ER, 1996, CIRCULATION, V94, P227
[9]   Development and clinical application of the MicroMed DeBakey VAD [J].
Noon, GP ;
Morley, D ;
Irwin, S ;
Benkowski, R .
CURRENT OPINION IN CARDIOLOGY, 2000, 15 (03) :166-171
[10]   Clinical experience with the MicroMed DeBakey ventricular assist device [J].
Noon, GP ;
Morley, DL ;
Irwin, S ;
Abdelsayed, SV ;
Benkowski, RJ ;
Lynch, BE .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S133-S138