Absolute CD4 T-Cell counting in resource-poor settings - Direct volumetric measurements versus bead-based clinical flow cytometry instruments

被引:54
作者
Dieye, TN
Vereecken, C
Diallo, AA
Ondoa, P
Diaw, PA
Camara, M
Karam, F
Mboup, S
Kestens, L
机构
[1] Le Dantec Univ, Teaching Hosp, Immunol Unit, Lab Bacteriol Virol, Dakar, Senegal
[2] Inst Trop Med, Dept Microbiol, Immunol Lab, B-2000 Antwerp, Belgium
关键词
CD4; count; HIV; affordable flow cytometry;
D O I
10.1097/01.qai.0000160515.20581.ad
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Flow cytometry is an accurate but expensive method to determine absolute CD4 cell counts. We compared different methods to measure absolute CD4 counts in blood samples from HIV-infected and uninfected subjects using a research/clinical flow cytometer (FACScan); a dedicated clinical instrument (FACSCount); and a volumetric, mobile, open-system flow cytometer equipped with 3 fluorescence and 2 light scatter detectors (Cyflow SL blue). The FACScan and Cyflow were used as single-platform instruments, but they differ in running cost, which is a central factor for resource-poor settings. Direct volumetric and bead-based CD4 measurements on the Cyflow were compared with 2 bead-based single-platform CD4 measurements on the FACSCount and on FACScan (TruCount) in "Le Dantec" Hospital, Dakar, Senegal, using whole blood samples from 102 HIV+ and 28 HIV- subjects. The agreement between the various measurement methods was evaluated by Bland-Altman analysis. Volumetric CD4 measurements on the Cyflow using a no-lyse-no-wash (NLNW) procedure and a lyse-no-wash (LNW) procedure correlated well with each other (R-2 = 0.98) and with CD4 measurements on the FACSCount (R-2 = 0.97) and FACScan (R-2 = 0.97), respectively. Red blood cell lysis had no negative effect on the accuracy of absolute CD4 counting on the Cyflow. An excellent correlation was observed between bead-based CD4 measurements on the Cyflow and CD4 measurements on the FACSCount (R-2 = 0.99) and FACScan (R-2 = 0.99). Rigid internal and external quality control monitoring and adequate training of technicians were considered essential to generate accurate volumetric CD4 measurements on the Cyflow.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Brando B, 2000, CYTOMETRY, V42, P327, DOI 10.1002/1097-0320(20001215)42:6<327::AID-CYTO1000>3.0.CO
[3]  
2-F
[4]  
Cassens U, 2004, ANTIVIR THER, V9, P395
[5]   Monitoring of human immunodeficiency virus infection in resource-constrained countries [J].
Crowe, S ;
Turnbull, S ;
Oelrichs, R ;
Dunne, A .
CLINICAL INFECTIOUS DISEASES, 2003, 37 :S25-S35
[6]   Comparative assessment of five alternative methods for CD4+ T-lymphocyte enumeration for implementation in developing countries [J].
Didier, JM ;
Kazatchkine, MD ;
Demouchy, C ;
Moat, C ;
Diagbouga, S ;
Sepulveda, C ;
Di Lonardo, AM ;
Weiss, L .
JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2001, 26 (02) :193-195
[7]   Prognosis of HIV-1-infected patients starting highly active antiretroviral therapy:: a collaborative analysis of prospective studies [J].
Egger, M ;
May, M ;
Chêne, G ;
Phillips, AN ;
Ledergerber, B ;
Dabis, F ;
Costagliola, D ;
Monforte, AD ;
de Wolf, F ;
Reiss, P ;
Lundgren, JD ;
Justice, AC ;
Staszewski, S ;
Leport, C ;
Hogg, RS ;
Sabin, CA ;
Gill, MJ ;
Salzberger, B ;
Sterne, JAC .
LANCET, 2002, 360 (9327) :119-129
[8]   CD45-assisted PanLeucogating for accurate, cost-effective dual-platform CD4+T-cell enumeration [J].
Glencross, D ;
Scott, LE ;
Jani, IV ;
Barnett, D ;
Janossy, G .
CYTOMETRY, 2002, 50 (02) :69-77
[9]   Individual patient-dependent influence of erythrocyte lysing procedures on flow-cytometric analysis of leukocyte subpopulations [J].
Göhde, W ;
Cassens, U ;
Lehman, LG ;
Traoré, Y ;
Göhde, W ;
Berkes, P ;
Westerberg, C ;
Greve, B .
TRANSFUSION MEDICINE AND HEMOTHERAPY, 2003, 30 (04) :165-170
[10]   Comparison of a new, affordable flow cytometric method and the manual magnetic bead technique for CD4 T-lymphocyte counting in a northern Nigerian setting [J].
Imade, GE ;
Badung, B ;
Pam, S ;
Agbaji, O ;
Egah, D ;
Sagay, AS ;
Sankalé, JL ;
Kapiga, S ;
Idoko, J ;
Kanki, P .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (01) :224-227