Performance study of diffusive gradients in thin films for 55 elements

被引:181
作者
Garmo, OA [1 ]
Royset, O
Steinnes, E
Flaten, TP
机构
[1] Norwegian Univ Sci & Technol, Dept Chem, N-7491 Trondheim, Norway
[2] Norwegian Inst Water Res, N-0411 Oslo, Norway
关键词
D O I
10.1021/ac026374n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The technique of diffusive gradients in thin films (DGT) is a fairly new and useful tool for in situ measurements of labile metal ions in water. The applicability of DGTs was investigated by comparing independently determined or estimated diffusion coefficients with DGT effective diffusion coefficients (D-DGT) for 55 elements. The DGTs were exposed at a controlled fluid velocity of 0.1 m s(-1) and a concentration of 1 ng mL(-1) at four pH levels between 4.7 and 6.0, and the DDGT values were determined from the uptake by the sampler. The measured DDGT values for the elements Co, Ni, Cu, Zn, Cd, Ph, Al, Mn, and Ga were close to previously published values with some deviations for Ph and Zn. The uptake of V, Cr, Fe, U, Mo, Ti, Ba, and Sr varied with pH, and there were some experimental problems that require further investigations. A novel set of DDGT values for the lanthanides (La, Ce, Pr, Nd, Sm, Eu, Gd, Th, Dy, Ho, Er, Tm, Th, Yb, Lu, Y) was established. The DDGT values for these were about 10-15% lower than for free ions in water and indicate that diffusion coefficients of metal ions in the agarose polyacrylamide diffusive hydrogel are 10-15% lower than in water. The high consistency of the data for the lanthanides establishes these elements as new performance test metals for the DGT sampler. The accumulation of the elements Li, Na, K, Rb, Mg, Ca, B, Tl, P, S, As, Bi, Se, Si, Sn, Sb, Te, Zr, Nb, Hf, Ta, W, Th, and Ag was low (DDGT lower than 10% of theoretical values). A more efficient elution procedure using concentrated nitric acid for the absorbent gel was established, with elution efficiencies between 95 and 100% for most metals. For deployment times of 24 h, detection limits from 0.001 to 1 ng mL(-1) were achieved with moderate precautions to prevent contamination.
引用
收藏
页码:3573 / 3580
页数:8
相关论文
共 22 条
[11]  
LEVICH VG, 1962, PHYSICOCHEM HYDRODYN, P59
[12]  
LEVICH VG, 1962, PHYSICOCHEM HYDRODYN, P9
[13]  
LI Y, 2002, GEOCHIM COSMOCHIM AC, V38, P703
[14]  
OLOFSSON R, 2001, POST EUR WINT C PLAS
[15]  
ROBINSON RA, 1959, ELECTROLYTIC SOLUTIO
[16]  
ROYSET O, 2003, UNPUB NORWEGIAN I WA
[17]  
ROYSET O, 2002, PASSIVE SAMPLING MET
[18]   Some examples of the use of amphoteric ion-exchange resins for inorganic separations [J].
Samczynski, Z ;
Dybczynski, R .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :157-167
[19]  
VANDECASTEELE C, 1993, MODERN METHODS TRACE, P36
[20]   Diffusional characteristics of hydrogels used in DGT and DET techniques [J].
Zhang, H ;
Davison, W .
ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) :329-340