Quantitative Evaluation of Regional Left Ventricular Function Using Three-Dimensional Speckle Tracking Echocardiography in Patients With and Without Heart Disease

被引:200
作者
Maffessanti, Francesco [2 ]
Nesser, Hans-Joachim [1 ]
Weinert, Lynn
Steringer-Mascherbauer, Regina [1 ]
Niel, Johannes [1 ]
Gorissen, Willem [3 ]
Sugeng, Lissa
Lang, Roberto M.
Mor-Avi, Victor [1 ]
机构
[1] Publ Hosp Elisabethinen, Linz, Austria
[2] Politecn Milan, I-20133 Milan, Italy
[3] Toshiba Med Syst, Zoetermeer, Netherlands
关键词
CARDIAC RESYNCHRONIZATION THERAPY; RADIAL STRAIN; MYOCARDIAL-INFARCTION; LONGITUDINAL STRAIN; MAGNETIC-RESONANCE; ROTATION; DYSSYNCHRONY; TWIST; HYPERTENSION; TORSION;
D O I
10.1016/j.amjcard.2009.07.060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although 2-dimensional (2D) speckle tracking echocardiography has been shown to be useful in the assessment of regional left ventricular function, it is limited by the assumption that speckles can be tracked frame-to-frame within the imaging plane, even though the cardiac motion is 3-dimensional (3D). Our goal was to evaluate new 3D-speckle tracking echocardiographic (STE) software by (1) comparing the regional wall motion measurements against 2D-STE images, and (2) testing its ability to identify regional wall motion abnormalities. The 2D images and real-time 3D data sets (Toshiba) obtained from 32 subjects were analyzed to measure segmental radial and longitudinal displacements and rotation, as well as the radial, longitudinal, and circumferential strains. The intertechnique comparisons included regression and Bland-Altman analyses. Additionally, cardiac magnetic resonance images (Siemens 1.5 T) acquired the same day were reviewed by an expert who classified the segments as normal or abnormal. The values of each 3D-STE index were compared between the normal and abnormal segments. The 3D-STE and 2D-STE indexes did not correlate well (r = 0.16 to 0.76) and showed wide limits in intertechnique agreement (2 SD: 5 to 6 mm for displacements, 14 degrees rotation, 17% to 52% strains) despite only minimal biases, indicating that these 2 techniques are not interchangeable. In normal segments, 3D-STE showed greater displacements, reflecting the out-of-plane motion component; smaller SDs, indicating tighter normal ranges; and a gradual decrease in radial and longitudinal displacement and a reversal in rotation from the base to the apex. In the abnormal segments, all 3D-STE indexes were reduced, reaching significance for 5 of 6 indexes. In conclusion, this is the first study to evaluate the new 3D-STE technique for measurement of regional wall motion indexes. Our findings have demonstrated its superiority over 2D-STE. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;104:1755-1762)
引用
收藏
页码:1755 / 1762
页数:8
相关论文
共 30 条
  • [1] Role of tissue Doppler and strain echocardiography in current clinical practice
    Abraham, Theodore P.
    Dimaano, Veronica L.
    Liang, Hsin-Yueh
    [J]. CIRCULATION, 2007, 116 (22) : 2597 - 2609
  • [2] Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging
    Amundsen, BH
    Helle-Valle, T
    Edvardsen, T
    Torp, H
    Crosby, J
    Lyseggen, E
    Stoylen, A
    Ihlen, H
    Lima, JAC
    Smiseth, OA
    Slordahl, SA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 789 - 793
  • [3] Burns AT, 2008, EUR HEART J, V29, P825, DOI 10.1093/eurheartj/ehn004
  • [4] Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    Cerqueira, MD
    Weissman, NJ
    Dilsizian, V
    Jacobs, AK
    Kaul, S
    Laskey, WK
    Pennell, DJ
    Rumberger, JA
    Ryan, T
    Verani, MS
    [J]. CIRCULATION, 2002, 105 (04) : 539 - 542
  • [5] 3-D correlation-based speckle tracking
    Chen, X
    Xie, H
    Erkamp, R
    Kim, K
    Jia, C
    Rubin, JM
    O'Donnell, M
    [J]. ULTRASONIC IMAGING, 2005, 27 (01) : 21 - 36
  • [6] Assessment of left ventricular dyssynchrony by speckle tracking strain imaging - Comparison between longitudinal, circumferential, and radial strain in cardiac resynchronization therapy
    Delgado, Victoria
    Ypenburg, Claudia
    van Bommel, Rutger J.
    Tops, Laurens F.
    Mollema, Sjoerd A.
    Marsan, Nina Ajmone
    Bleeker, Gabe B.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (20) : 1944 - 1952
  • [7] Assessment of longitudinal and radial ventricular dyssynchrony in ischemic and nonischemic chronic Systolic heart failure: A two-dimensional echocardiographic speckle-tracking strain study
    Donal, Erwan
    Tournoux, Francois
    Leclercq, Christophe
    De Place, Christian
    Solnon, Aude
    Derumeaux, Genevive
    Mabo, Philippe
    Cohen-Solal, Alain
    Daubert, Jean-Claude
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (01) : 58 - 65
  • [8] Relation between left ventricular regional radial function and radial wall motion abnormalities using two-dimensional speckle tracking in children with idiopathic dilated cardiomyopathy
    Friedberg, Mark Kevin
    Slorach, Cameron
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (03) : 335 - 339
  • [9] Assessment of subendocardial vs. subepicardial left ventricular rotation and twist using two-dimensional speckle tracking echocardiography: comparison with tagged cardiac magnetic resonance
    Goffinet, Celine
    Chenot, Fabien
    Robert, Annie
    Pouleur, Anne-Catherine
    de Waroux, Jean-Benoit le Polain
    Vancrayenest, David
    Gerard, Olivier
    Pasquet, Agnes
    Gerber, Bernhard L.
    Vanoverschelde, Jean-Louis
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (05) : 608 - 617
  • [10] Assessment of regional rotation patterns improves the understanding of the systolic and diastolic left ventricular function: an echocardiographic speckle-tracking study in healthy individuals