MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips

被引:104
作者
Toms, A. P. [1 ]
Marshall, T. J. [1 ]
Cahir, J. [1 ]
Darrah, C. [2 ]
Nolan, J. [2 ]
Donell, S. T. [3 ]
Barker, T. [4 ]
Tucker, J. K. [2 ]
机构
[1] Norfolk & Norwich Univ Hosp, Dept Radiol, Norwich NR4 7UY, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Dept Orthopaed, Norwich NR4 7UY, Norfolk, England
[3] Norfolk & Norwich Univ Hosp, Dept Pathol, Norwich NR4 7UY, Norfolk, England
[4] Univ E Anglia, Inst Hlth, Norwich NR4 7TJ, Norfolk, England
关键词
D O I
10.1016/j.crad.2007.07.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
AIM: To perform a retrospective review of all the conventional radiographic and magnetic resonance imaging (MRI) studies performed in patients with early postoperative pain following cobalt-chrome metal-on-metal total hip arthroplasty. METHODS: A retrospective review of the radiology, surgical findings and histology in nineteen patients who had undergone a total of 20 hip arthroplasties using a cobalt-chromium on cobalt-chromium alloy prosthesis was undertaken. RESULTS: Measures of implant placement on the immediate postoperative radiographs were all within the normal ranges (n = 20). Where more than one postoperative radiograph was available statistical analysis revealed no evidence of progressive change before the MRI examination (14). The median postoperative time to MRI was 35 months (range 11-63 months). Abnormalities were demonstrated using MRI in all symptomatic hips (n = 20). These comprised: periprosthetic fluid collections (20), which were isointense to muscle on T1-weighted images in 19 cases and hyperintense on T2-weighted images in 18 cases, periprosthetic bone marrow oedema (n = 6), muscle oedema (n = 4), avulsion of the gluteus minimus and medius tendons (n = 5), atrophy of piriformis (n = 15) and obturator internus (n = 17), and fracture of the medial. calcar (n = 1). Operative findings in patients who had undergone revision surgery (n = 15) included: fluid-filled cavities (n = 11), soft tissue necrosis (n = 8), gluteal tendon avulsion (n = 5), proximal femoral, diaphyseal necrosis (n = 4), and pitting and corrosion of the femoral. stems (n = 8), which were, in all cases, firmly fixed to the cement mantle. Histology revealed viable tissue in six hips with necrosis (n = 12) and fibrin deposition (n = 15) being the predominate findings. Other findings included a perivascular lymphocytic infiltrate (n = 5), features of active inflammation (n = 4), and metallosis (n = 1). CONCLUSION: A significant number of patients with metal-on-metal hip replacements presented with early postoperative pain because of an abnormal soft-tissue reaction. MRI can demonstrate characteristic soft-tissue disease in these patients where conventional radiographs are frequently normal. (c) 2007 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 39 条
[1]
Allen A M, 1995, J South Orthop Assoc, V4, P96
[2]
IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[3]
PSEUDOBURSAE - A USEFUL FINDING IN PATIENTS WITH PAINFUL HIP-ARTHROPLASTY [J].
BERQUIST, TH ;
BENDER, CE ;
MAUS, TP ;
WARD, EM ;
RAND, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :103-106
[4]
A benign psoas mass following metal-on-metal resurfacing of the hip [J].
Boardman, DR ;
Middleton, FR ;
Kavanagh, TG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (03) :402-404
[5]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[6]
BULLOUGH PG, 2003, ORTHOPAEDIC PATHOLOG, P327
[7]
Radiological features predictive of aseptic loosening in cemented Charnley femoral stems [J].
Chambers, IR ;
Fender, D ;
McCaskie, AW ;
Reeves, BC ;
Gregg, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :838-842
[8]
MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence [J].
Chang, SD ;
Lee, MJ ;
Munk, PL ;
Janzen, DL ;
MacKay, A ;
Xiang, QS .
SKELETAL RADIOLOGY, 2001, 30 (04) :213-218
[9]
Czerny C, 1999, Top Magn Reson Imaging, V10, P214, DOI 10.1097/00002142-199908000-00003
[10]
An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27