Bronchial anastomotic complications in lung transplant recipients: Virtual bronchoscopy for noninvasive assessment

被引:62
作者
McAdams, HP
Palmer, SM
Erasmus, JJ
Patz, EF
Connolly, JE
Goodman, PC
Delong, DM
Tapson, VF
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
关键词
bronchi; CT; bronchoscopy; computed tomography (CT); three-dimensional; lung; diseases;
D O I
10.1148/radiology.209.3.9844660
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of virtual bronchoscopy (VB) with that of axial computed tomography (CT) in the assessment of bronchial anastomotic complications in lung transplant recipients. MATERIALS AND METHODS: Twenty-seven bronchial anastomoses in ii patients were evaluated with helical CT. Axial CT and VB images were evaluated for surface irregularity and the presence, length, and severity of stenosis. findings were correlated with the results of fiberoptic bronchoscopy (FOB). RESULTS: There were 12 anastomotic stenoses at FOE. Pooled accuracy (among all four readers) of VB and axial CT for diagnosis of clinically relevant stenosis was 97% and 80%, respectively, at the right bronchial anastomoses and 92% and 75%, respectively, at the left bronchial anastomoses. Pooled accuracy of VB and axial CT for stenosis length was 72% and 62%, respectively, at the right anastomoses and 81% and 69%, respectively, at the left anastomoses. These differences were not statistically significant. Both the VB and axial CT images showed surface irregularities when anastomotic infection (n = 2)or dehiscence (n = 1) was present but resulted in an overdiagnosis of mucosal abnormalities when anastomoses were normal. CONCLUSION: VB was slightly more accurate than axial CT for diagnosis of clinically relevant stenoses at bronchial anastomoses in lung transplant recipients. However, because VB is not 100% accurate and has no role in the diagnosis of infection or dehiscence, it probably will not replace FOE for assessment of bronchial anastomotic complications in this population.
引用
收藏
页码:689 / 695
页数:7
相关论文
共 33 条
[1]   Bronchial wall thickness: Appropriate window settings for thin-section CT and radiologic-anatomic correlation [J].
Bankier, AA ;
Fleischmann, D ;
Mallek, R ;
Windisch, A ;
Winkelbauer, FW ;
Kontrus, M ;
Havelec, L ;
Herold, CJ ;
Hubsch, P .
RADIOLOGY, 1996, 199 (03) :831-836
[2]   Three-dimensional computed tomography bronchoscopy using clinical datasets: a comparison with fibreoptic bronchoscopy [J].
Chinn, RJS ;
Yang, GZ ;
Congleton, J ;
Mellor, J ;
Geddes, DM ;
Hansell, DM .
CLINICAL RADIOLOGY, 1997, 52 (11) :830-836
[3]   ENDOSCOPIC MANAGEMENT OF BRONCHIAL STENOSIS AFTER DOUBLE LUNG TRANSPLANTATION [J].
COLT, HG ;
JANSSEN, JP ;
DUMON, JF ;
NOIRCLERC, MJ .
CHEST, 1992, 102 (01) :10-16
[4]   IMPROVED AIRWAY HEALING AFTER LUNG TRANSPLANTATION - AN ANALYSIS OF 348 BRONCHIAL ANASTOMOSES [J].
DATE, H ;
TRULOCK, EP ;
ARCIDI, JM ;
SUNDARESAN, S ;
COOPER, JD ;
PATTERSON, GA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (05) :1424-1433
[5]  
Efron B., 1982, SOC IND APPL MATH CB, V38, DOI [DOI 10.1137/1.9781611970319, 10.1137/1.9781611970319]
[6]   Central airway stenoses: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients [J].
Ferretti, GR ;
Knoplioch, J ;
Bricault, I ;
Brambilla, C ;
Coulomb, M .
EUROPEAN RADIOLOGY, 1997, 7 (06) :854-859
[7]   Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: Opportunities and limitations [J].
Fleiter, T ;
Merkle, EM ;
Aschoff, AJ ;
Lang, G ;
Stein, M ;
Gorich, J ;
Liewald, F ;
Rilinger, N ;
Sokiranski, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) :1591-1595
[8]   Airway problems in lung transplantation [J].
Fullerton, DA ;
Campbell, DN .
SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 17 (02) :187-196
[9]   DETECTION OF BRONCHIAL ABNORMALITIES - COMPARISON OF CT AND BRONCHOSCOPY [J].
HENSCHKE, CI ;
DAVIS, SD ;
AUH, Y ;
ROMANO, P ;
WESTCOTT, J ;
BERKMEN, YM ;
KAZAM, E .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (03) :432-435
[10]  
HIGGINS R, 1994, J HEART LUNG TRANSPL, V13, P774