Development of new endovascular techniques for repair of abdominal aortic aneurysm (AAA) requires the use of experimental models. Stereolithography is a rapid prototyping technique used in industry to prototype parts during the design phase. A stereolithography apparatus (STL) employs laser technology to build a digital model layer by layer with photopolymer resin. The purpose of this study was to use this technology to produce a life-size AAA model. Data were acquired by CT scan and stored in DICOM 3 format. Specifically designed software was used for 3-D imaging and conversion of data to a standard STL format. Two replicas were made: one to scale and the other 3 mm larger. The final model was made by pouring silicone rubber or polyurethane into the mold over the life-size model so as to obtain a sturdy, life-size, soft, transparent plastic casting. Arterial models made for living subjects with these rapid prototyping techniques can be used to simulate surgical procedures, calibrate imaging modalities, and design new stent grafts.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 26 条
[1]
BEEBE HG, 1995, J ENDOVASC SURG, V2, P134
[2]
Preliminary experience with medical applications of rapid prototyping by selective laser sintering [J].
Berry, E ;
Brown, JM ;
Connell, M ;
Craven, CM ;
Efford, ND ;
Radjenovic, A ;
Smith, MA .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (01) :90-96
[3]
BRENAN J, 1998, J ENDOVASC SURG S1, V5, P1
[4]
Broeders IAMJ, 1997, J ENDOVASC SURG, V4, P252, DOI 10.1583/1074-6218(1997)004<0252:PSOGFT>2.0.CO
[5]
2
[6]
CHILDS THC, 1994, ANN CIRP, V43, P163
[7]
Computer aided design and fabrication of models for in vitro studies of vascular fluid dynamics [J].
Chong, CK ;
Rowe, CS ;
Sivanesan, S ;
Rattray, A ;
Black, RA ;
Shortland, AP ;
How, TV .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H1) :1-4
[8]
Development of a simulator for endovascular repair of abdominal aortic aneurysms [J].
Chong, CK ;
How, TV ;
Black, RA ;
Shortland, AP ;
Harris, PL .
ANNALS OF BIOMEDICAL ENGINEERING, 1998, 26 (05) :798-802
[9]
Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial [J].
D'Urso, PS ;
Barker, TM ;
Earwaker, WJ ;
Bruce, LJ ;
Atkinson, RL ;
Lanigan, MW ;
Arvier, JF ;
Effeney, DJ .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (01) :30-37
[10]
Animal models of aneurysms [J].
Dobrin, PB .
ANNALS OF VASCULAR SURGERY, 1999, 13 (06) :641-648