Selective extraction of small proteins from biological samples using a novel restricted access column with cation exchange properties

被引:11
作者
Grimm, CH
Boos, KS
Apel, C
Unger, KK
Önnerfjord, P
Heintz, L
Edholm, LE
Marko-Varga, G
机构
[1] AstraZeneca R&D Lund, Dept Cell & Mol Biol, S-22187 Lund, Sweden
[2] Univ Munich, Klinikum Grosshadern, Inst Klin Chem, D-81366 Munich, Germany
[3] Univ Mainz, Inst Anorgan Chem & Analyt Chem, D-55099 Mainz, Germany
[4] Univ Lund, Dept Cell & Mol Biol, S-22100 Lund, Sweden
关键词
column liquid chromatography; restricted access cation exchanger; sample clean-up; extraction of proteins;
D O I
10.1007/BF02490993
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of proteins utilising a polymer-based restricted access support material with ion exchange properties (IERAM) is outlined. Solid phase extraction coupled on-line with a microbore reversed phase HPLC system for the quantitation of small marker proteins is demonstrated. The cation-exchange restricted access packings were characterised with respect to their adsorption and desorption kinetics. The IERAM material was also investigated by capacity, selectivity, and biocompatibility determinations when applied to the quantification of small molecular weight proteins such as cytochrome C, Lysozyme, Ribonuclease A Myoglobin, Insulin, human serum albumin, and a Tryptic inhibitor. The integrated system was coupled to mass identity of selected proteins by MALDI-TOF mass spectrometry. The chromatographic outlet was interfaced to an "Interplate" fractionation collecter that sampled 1 muL volumes directly onto the MALDI target plate. The fully automated coupled column system was run unattended overnight and applied to protein quantitations in human plasma samples. Recovery data for a selected number of proteins varied between 90-96% (n = 10) with a limit of quantification around 2 muM with an injection volume of 100 muL. The RSD data were typically less than 8% at a 50 muM protein level (n = 7).
引用
收藏
页码:703 / 709
页数:7
相关论文
共 13 条
[1]  
APEL C, 1998, THESIS J GUTENBERG U
[2]   MICROPOROUS HYPERCROSSLINKED POLYSTYRENE STYROSORB AS A RESTRICTED ACCESS PACKING IN SAMPLE CLEANUP FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. EVALUATION OF RESTRICTED ACCESS PROPERTIES [J].
BETH, M ;
UNGER, KK ;
TSYURUPA, MP ;
DAVANKOV, VA .
CHROMATOGRAPHIA, 1993, 36 :351-355
[3]   Integrated microanalytical technology enabling rapid and automated protein identification [J].
Ekström, S ;
Önnerfjord, P ;
Nilsson, J ;
Bengtsson, M ;
Laurell, T ;
Marko-Varga, G .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :286-293
[4]   An integrated coupled column liquid chromatography system for the determination of leukotriene metabolites in biological samples [J].
Heintz, L ;
Osterlind, E ;
Alkner, U ;
MarkoVarga, G .
CHROMATOGRAPHIA, 1997, 46 (7-8) :365-373
[5]  
Önnerfjord P, 1999, RAPID COMMUN MASS SP, V13, P315
[6]   BIOANALYSIS OF DIGOXIN AND ITS METABOLITES USING DIRECT SERUM INJECTION COMBINED WITH LIQUID-CHROMATOGRAPHY AND ONLINE IMMUNOCHEMICAL DETECTION [J].
OOSTERKAMP, AJ ;
IRTH, H ;
BETH, M ;
UNGER, KK ;
TJADEN, UR ;
VANDEGREEF, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 653 (01) :55-61
[7]   Simultaneous determination of cross-reactive leukotrienes in biological matrices using on-line liquid chromatography immunochemical detection [J].
Oosterkamp, AJ ;
Irth, H ;
Heintz, L ;
MarkoVarga, G ;
Tjaden, UR ;
vanderGreef, J .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4101-4106
[8]  
Oosterkamp AJ, 1997, J CLIN LIGAND ASSAY, V20, P40
[9]   ONLINE COUPLING OF LIQUID-CHROMATOGRAPHY TO BIOCHEMICAL ASSAYS BASED ON FLUORESCENT-LABELED LIGANDS [J].
OOSTERKAMP, AJ ;
IRTH, H ;
TJADEN, UR ;
VANDERGREEF, J .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4295-4301
[10]  
OS KS, 1997, LC GC, V15, P602