A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces

被引:146
作者
Lewis, T. [2 ,3 ]
Griffith, C. [1 ]
Gallo, M. [2 ,3 ]
Weinbren, M. [2 ,3 ]
机构
[1] Univ Wales Inst, Sch Appl Sci, Cardiff CF5 2YB, S Glam, Wales
[2] Univ Hosp Coventry, Coventry, W Midlands, England
[3] Warwickshire NHS Trust Hosp, Coventry, W Midlands, England
关键词
ATP; benchmark; cleaning; environmental surfaces;
D O I
10.1016/j.jhin.2008.03.013
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Hospital cleaning continues to attract patient, media and political attention. In the UK it is still primarily assessed via visual inspection, which can be misleading. Calls have therefore been made for a more objective approach to assessing surface cleanliness. To improve the management of hospital cleaning the use of adenosine triphosphate (ATP) in combination with microbiological analysis has been proposed, with a general ATIP benchmark value of 500 relative tight units (RLU) for one combination of test and equipment. In this study, the same test combination was used to assess cleaning effectiveness in a 1300-bed teaching hospital after routine and modified cleaning protocols. Based upon the ATIP results a revised stricter pass/fail benchmark of 250 RLU is proposed for the range of surfaces used in this study. This was routinely achieved using modified best practice cleaning procedures which also gave reduced surface counts with, for example, aerobic colony counts reduced from >100 to <2.5 cfu/cm(2), and counts of Staphylococcus aureus reduced from up to 2.5 to <1 cfu/cm(2) (95% of the time). Benchmarking is linked to incremental quality improvements and both the original suggestion of 500 RLU and the revised figure of 250 RLU can be used by hospitals as part of this process. They can also be used in the assessment of novel. cleaning methods, such as steam cleaning and microfibre cloths, which have potential use in the National Health Service. (C) 2008 The Hospital Infection Society. Published by Elsevier Ltd. Att rights reserved.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 32 条
[1]  
[Anonymous], 2004, CLEAN HOSP LOW RAT I
[2]  
[Anonymous], CLEAN MANAGEMENT GUI
[3]  
[Anonymous], 2006, MANAGEMENT MULTIDRUG
[4]   Environmental contamination makes an important contribution to hospital infection [J].
Boyce, John M. .
JOURNAL OF HOSPITAL INFECTION, 2007, 65 :50-54
[5]  
*BRIT SOC ANT CHEM, 2007, BSAC METH ANT SUS TE, V6, P1
[6]  
Centers for Disease Control and Prevention (CDC), 2003, MMWR Recomm Rep, V52, P1
[7]  
COOPER RA, 2007, AM J INFECT CONT, V66, P352
[8]   How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals [J].
Dancer, SJ .
JOURNAL OF HOSPITAL INFECTION, 2004, 56 (01) :10-15
[9]   Role of environmental cleaning in controlling an outbreak of Acinetobacter baumannii on a neurosurgical intensive care unit [J].
Denton, M ;
Wilcox, MH ;
Parnell, P ;
Green, D ;
Keer, V ;
Hawkey, PM ;
Evans, I ;
Murphy, P .
JOURNAL OF HOSPITAL INFECTION, 2004, 56 (02) :106-110
[10]  
*DEP HLTH, 2004, REV GUID CONTR CLEAN