Ion spray mass spectrometry for elemental speciation in aqueous samples: Preliminary investigation of experimental parameters, matrix effects and metal-ligand complexation

被引:22
作者
Olesik, JW [1 ]
Thaxton, KK [1 ]
Olesik, SV [1 ]
机构
[1] OHIO STATE UNIV,DEPT CHEM,COLUMBUS,OH 43210
关键词
ion spray mass spectrometry; elemental speciation; aqueous samples; matrix effects; metal-ligand complexation; electrospray mass spectrometry;
D O I
10.1039/a606420e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion spray mass spectra obtained from aqueous solutions are discussed. Ion clusters with large numbers of water molecules, very few water molecules or bare elemental ions could be obtained by adjusting the sampling orifice voltage, the skimmer voltage or the position of the ion spray nebulizer relative to the sampling orifice. In some cases submillimeter changes in the position of the ion spray nebulizer can dramatically affect the nature of the spectra observed, There is evidence of declustering between the skimmer and first ion lens as well as between the sampling orifice and skimmer, Interpretation of the mass spectra must be carried out with care as potential spectral overlaps are common, Use of a triple quadrupole mass spectrometer allows assessment of potential spectral overlaps, Ni-EDTA complexation was investigated, The Ni+ signal correlated with the expected concentration of free metal ions in the solution not the total metal concentration even when relatively harsh conditions that produced bare metal ion spectra were used, Matrix effects due to high concentrations of NaCl and HCl were briefly investigated.
引用
收藏
页码:507 / 515
页数:9
相关论文
共 34 条
[1]   ELEMENTAL SPECIATION MEASUREMENTS WITH ELECTROSPRAY MASS-SPECTROMETRY - AN ASSESSMENT [J].
AGNES, GR ;
STEWART, II ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (11) :1347-1359
[2]   EFFECT OF OPERATING PARAMETERS ON ANALYTE SIGNALS IN ELEMENTAL ELECTROSPRAY MASS-SPECTROMETRY [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1995, 49 (03) :324-334
[3]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - PRELIMINARY-RESULTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1992, 46 (03) :401-406
[4]   DETERMINATION OF SOLUTION IONS BY ELECTROSPRAY MASS-SPECTROMETRY [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :655-661
[5]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - QUANTITATIVE ASPECTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :649-654
[6]   1ST STUDIES OF THE GAS-PHASE ION CHEMISTRY OF M3+ METAL-ION LIGANDS [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 101 (2-3) :325-336
[7]   STUDIES OF ALKALINE-EARTH AND TRANSITION-METAL M++ GAS-PHASE ION CHEMISTRY [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
JOURNAL OF CHEMICAL PHYSICS, 1990, 92 (10) :5900-5906
[8]   ION-MOLECULE CLUSTERS INVOLVING DOUBLY CHARGED METAL-IONS (M2+) [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 102 :251-267
[9]  
BLADES AT, 1991, ANAL CHEM, V63, P109
[10]   Comparison of electrospray and inductively coupled plasma sources for elemental analysis with mass spectrometric detection [J].
Brown, FB ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :633-641