Detection, quantification and confirmation of anabolic steroids in equine plasma by liquid chromatography and tandem mass spectrometry

被引:80
作者
Guan, FY
Uboh, CE
Soma, LR
Luo, Y
Rudy, J
Tobin, T
机构
[1] Univ Penn, Sch Vet Med, Dept Clin Studies, Kennett Sq, PA 19348 USA
[2] W Chester Univ, Dept Chem, PA Equine Toxicol & Res Ctr, W Chester, PA 19382 USA
[3] Univ Kentucky, Max H Gluck Equine Res Ctr, Lexington, KY 40546 USA
[4] Univ Kentucky, Dept Vet Sci, Lexington, KY 40546 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 829卷 / 1-2期
关键词
anabolic steroid; LC-MS; plasma; horse; doping control; THG; testosterone; boldenone;
D O I
10.1016/j.jchromb.2005.09.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Anabolic androgenic steroids are related to the male sex hormones and are abused in equine sports. In an effort to deter the abuse of anabolic steroids, a sensitive LC-MS/MS method was developed for detection, quantification and confirmation of eight major anabolic steroids (testosterone, normethandrolone, nandrolone, boldenone, methandrostenolone, tetrahydrogestrinone (THG), trenbolone, and stanozolol) in equine plasma. Formation of solvent adduct ions of the analytes was observed under electrospray ionization (ESI) conditions, and desolvation of the solvent adduct ions by source collision-induced decomposition (CID) increased the abundance of the [M + H](+) ions as well as the multiple-reaction monitoring (MRM) signals. ESI (+) and APCI (+) were compared with respect to sensitivity for the analytes and the former provided better sensitivity. The matrix effect on ion suppression or enhancement was evaluated, and was negligible. Confirmation of the analytes was performed using criteria of three ion transitions and LC retention time of each analyte. The limit of detection (LOD) and quantification (LOQ) was 25 pg/mL. The limit of confirmation (LOC) was 25 pg/mL for boldenone; 50 pg/mL for normethandrolone, nandrolone, and methandrostenolone; and 100 pg/mL for testosterone, THG, trenbolone, and stanozolol. The analytes were evaluated for stability and found to be stable in plasma for 24 It at room temperature, 13 days at 4 degrees C, and 34 days at -20 and -70 degrees C. The method was successfully applied to analyses of equine plasma samples for pharmacokinetics study. This method is sensitive and useful for detection, quantification and confirmation of these anabolic steroids in equine plasma. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 68
页数:13
相关论文
共 44 条
[1]  
Association of Racing Commissioners International, UN CLASS GUID FOR SU
[2]  
BENOIT E, 1985, ANN RECH VET, V16, P379
[3]   Determination of trenbolone and its metabolite in bovine fluids by liquid chromatography-tandem mass spectrometry [J].
Buiarelli, F ;
Cartoni, GP ;
Coccioli, F ;
De Rossi, A ;
Neri, B .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (01) :1-15
[4]   Tetrahydrogestrinone: discovery, synthesis, and detection in urine [J].
Catlin, DH ;
Sekera, MH ;
Ahrens, BD ;
Starcevic, B ;
Chang, YC ;
Hatton, CK .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (12) :1245-1249
[5]   Detection of norbolethone, an anabolic steroid never marketed, in athletes' urine [J].
Catlin, DH ;
Ahrens, BD ;
Kucherova, Y .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (13) :1273-1275
[6]  
Choi MH, 1998, RAPID COMMUN MASS SP, V12, P1749, DOI 10.1002/(SICI)1097-0231(19981130)12:22<1749::AID-RCM395>3.0.CO
[7]  
2-S
[8]   Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid [J].
Dams, R ;
Huestis, MA ;
Lambert, WE ;
Murphy, CM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (11) :1290-1294
[9]   Consequence of boar edible tissue consumption on urinary profiles of nandrolone metabolites.: II.: Identification and quantification of 19-norsteroids responsible for 19-norandrosterone and 19-noretiocholanolone excretion in human urine [J].
De Wasch, K ;
Le Bizec, B ;
De Brabander, H ;
André, F ;
Impens, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (16) :1442-1447
[10]  
*DPC DIAGN PROD CO, MAN COAT A COUNT TOT