Preserving the chromatographic integrity of high-speed supercritical fluid chromatography separations using time-of-flight mass spectrometry

被引:20
作者
Bolaños, BJ [1 ]
Ventura, MC [1 ]
Greig, MJ [1 ]
机构
[1] La Jolla Labs, Pfizer Global Res & Dev, San Diego, CA 92121 USA
来源
JOURNAL OF COMBINATORIAL CHEMISTRY | 2003年 / 5卷 / 04期
关键词
D O I
10.1021/cc020093b
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The advantage of high-speed time-of-flight-mass spectrometry (TOF-MS) detection for ultrafast qualitative supercritical fluid chromatography/mass spectrometry (SFC/MS) applications allows the superior resolving power of SFC to be exploited in high-throughput analysis. A chromatographic comparison of quadrupole MS and TOF-MS shows high-speed TOF total ion current data point sampling to be more indicative of fast SFC separations and corresponding short (1-2 s) baseline peak widths. Results shown for analysis of a six-compound mixture with two peaks eluting at 0.86 and 0.89 min exhibit >50% resolution by high-speed TOF data sampling, whereas the same peaks appear to coelute using quadrupole MS data sampling. Additionally, a marked improvement in the peak baseline widths is afforded by fast TOF data acquisition of 0.1 s/spectrum, resulting in a reduction in the baseline width, 1.6 s, of sulfanilamide in a four-compound mixture that is more than 2-fold greater than that achieved at the slower data acquisition of 0.5 s/spectrum. The resulting increase in resolution and improved peak shapes allow automatic integration routines to perform more effectively. For most classes of compounds amenable to high performance liquid chromatography, including druglike species, steroids, and polymers, the union of SFC with TOF-MS provides the maximum density of chemical information per unit time available with any high-speed chromatographic/mass spectrometric method.
引用
收藏
页码:451 / 455
页数:5
相关论文
共 12 条
[1]   The development of a semi-preparatory scale supercritical-fluid chromatograph for high-throughput purification of 'combi-chem' libraries [J].
Berger, TA ;
Fogleman, K ;
Staats, T ;
Bente, P ;
Crocket, I ;
Farrell, W ;
Osonubi, M .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2000, 43 (1-3) :87-111
[2]  
BERGER TA, 1995, PACKED COLUMN SFC, P45
[3]   Capillary electrochromatography of biomolecules with on-line electrospray ionization and time-of-flight mass spectrometry [J].
Choudhary, G ;
Horváth, C ;
Banks, JF .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :469-480
[4]   Peak distortion, data sampling errors and the integrator in the measurement of very narrow chromatographic peaks [J].
Dyson, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :321-340
[5]  
GERE DR, 1983, 8003 HP CO
[6]   Increasing bioanalytical throughput using pcSFC-MS/MS: 10 minutes per 96-well plate [J].
Hoke, SH ;
Tomlinson, JA ;
Bolden, RD ;
Morand, KL ;
Pinkston, JD ;
Wehmeyer, KR .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3083-3088
[7]   MASS-SPECTROMETRY ON THE CHROMATOGRAPHIC TIME SCALE - REALISTIC EXPECTATIONS [J].
HOLLAND, JF ;
ENKE, CG ;
ALLISON, J ;
STULTS, JT ;
PINKSTON, JD ;
NEWCOME, B ;
WATSON, JT .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :A997-&
[8]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[9]  
MORGAN DG, 2000, 10 INT S EXH SUP FLU
[10]  
NOVAK J, 1988, CHROMATOGRAPHY SCI S, V41, P187