Precision assessment of biofluid viscosity measurements using molecular rotors

被引:25
作者
Akers, WJ [1 ]
Haidekker, MA [1 ]
机构
[1] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 03期
关键词
D O I
10.1115/1.1894366
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood viscosity changes with many pathologic conditions, but its importance has not been fully investigated because the current methods of measurement are poorly suited for clinical applications. The use of viscosity-sensitive fluorescent molecular rotors to determine fluid viscosity in a nonmechanical manner has been investigated recently, but it is unknown how the precision of the fluorescence-based method compares to established mechanical viscometry. Human blood plasma viscosity was modulated with high-viscosity plasma expanders, dextran, pentastarch, and hetastarch. The samples were divided into a calibration and a test set. The relationship between fluorescence emission and viscosity was established using the calibration set. Viscosity of the test set was determined by and by cone-and-plate viscometer and the precision of both methods compared. Molecular rotor fluorescence intensity showed a power law relationship with solution viscosity. Mechanical measurements deviated from the theoretical viscosity value by less than 7.6%, while fluorescence-based measurements deviated by less than 6%. The average coefficient of variation was 69% (mechanical measurement) and 3.4% to 3.8% (fluorescence-based measurement, depending on the molecular rotor used). Fluorescence-based viscometry exhibits comparable precision to mechanical viscometry. Fluorescence viscometry does not apply shear and is therefore more practical for biofluids which have apparent non-Newtonian properties. In addition, fluorescence instrumentation makes very fast serial measurements possible, thus promising new areas of application in laboratory and clinical settings.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 25 条
[1]   A molecular rotor as viscosity sensor in aqueous colloid solutions [J].
Akers, W ;
Haidekker, MA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (03) :340-345
[2]  
Cokelet G.R., 1972, BIOMECHANICS ITS F O, P63
[3]  
Dintenfass L, 1989, Aging (Milano), V1, P99
[4]   ABSTENTION FROM CHRONIC CIGARETTE-SMOKING NORMALIZES BLOOD RHEOLOGY [J].
ERNST, E ;
MATRAI, A .
ATHEROSCLEROSIS, 1987, 64 (01) :75-77
[5]   DOSE EFFECT RELATIONSHIP BETWEEN SMOKING AND BLOOD RHEOLOGY [J].
ERNST, E ;
MATRAI, A ;
SCHMOLZL, C ;
MAGYAROSY, I .
BRITISH JOURNAL OF HAEMATOLOGY, 1987, 65 (04) :485-487
[6]  
FORSTER T, 1971, Z PHYS CHEM NEUE FOL, V75, P63
[7]   Hydrophilic molecular rotor derivatives - synthesis and characterization [J].
Haidekker, MA ;
Brady, TP ;
Chalian, SH ;
Akers, W ;
Lichlyter, D ;
Theodorakis, EA .
BIOORGANIC CHEMISTRY, 2004, 32 (04) :274-289
[8]   A novel approach to blood plasma viscosity measurement using fluorescent molecular rotors [J].
Haidekker, MA ;
Tsai, AG ;
Brady, T ;
Stevens, HY ;
Frangos, JA ;
Theodorakis, E ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (05) :H1609-H1614
[9]  
HARKNESS J, 1971, Biorheology, V8, P171
[10]  
HEILMANN L, 1986, ZBL GYNAKOL, V108, P393